MX-2300/2700 N/G SIMULATION 7 – 39
27-7
Purpose
: Setting
Function (Purpose)
: Used to set the FSS functions (enable, alert
callout).
Section
: Communication (RIC/MODEM)
Item
: Specifications
Operation/Procedure
1)
When the machine enters the simulation, the following screen
is displayed.
2)
Select an item to be set with [
↑
] and [
↓
] buttons.
The highlighted section of the set value is changed and the
value is displayed in the setting area.
* When there is an item over [
↑
], the display becomes active
and shifts to another item.
When there is no item over [
↑
], the display grays out and the
operation is disabled.
When there is an item under [
↓
], the display becomes active
and shifts to another item.
When there is no item under [
↓
], the display grays out and
the operation is disabled.
3)
Enter the set value with 10-key.
* Press [C] key to clear the entered value.
* In the FSS function setting, change from YES (0) to NO (1)
cannot be made.
4)
When [OK] button is pressed, the current set value is saved to
EEPROM and RAM.
* When [COLOR], or [BLACK] key is pressed, the current set
value is saved to EEPROM and RAM.
* When [CA] key or [SYSTEM SETTINGS] key is pressed to
exit the simulation, the machine is rebooted.
<Setting range and default value of each value>
(*): In the FSS function setting, change from Disable to Enable can
be made, but change from Disable to Enable cannot be made.
<Alert item>
27-9
Purpose
: Setting
Function (Purpose)
: Used to set the threshold value for deter-
mining whether the paper feed time
between sensors is recorded or not and the
threshold value for determining whether the
gain adjustment retry number is recorded
or not.
Section
: —
Item
: Specifications
Operation/Procedure
1)
When the machine enters the simulation, the following screen
is displayed.
2)
Select an item to be set with [
↑
] and [
↓
] buttons.
The highlighted section of the set value is changed and the
value is displayed in the setting area.
* When there is an item over [
↑
], the display becomes active
and shifts to another item.
When there is no item over [
↑
], the display grays out and the
operation is disabled.
When there is an item under [
↓
], the display becomes active
and shifts to another item.
When there is no item under [
↓
], the display grays out and
the operation is disabled.
3)
Enter the set value with 10-key.
* Press [C] key to clear the entered value.
4)
When [OK] button is pressed, the current set value is saved to
EEPROM and RAM.
After completion of setting, [OK] button returns to the normal
display.
* When [COLOR], or [BLACK] key is pressed, the current set
value is saved to EEPROM and RAM.
<Setting range and default value of each value>
* Item A: 0% is the standard passing time between sheets. 100%
is the time for judgment as a JAM between sheets.
Item
Display
Content
Setting
range
Default
value
A
FUNCTION
(0:YES 1:NO)
0
FSS function is
enabled.
0 to 1
1
(NO)
1
FSS function is
disabled. (*)
B
ALERT
(0:YES 1:NO)
0
Alert callout is enabled.
0 to 1
0
(YES)
1
Alert callout is disabled.
Item
Send timing
No cause of callout
Initial/Trouble/Continuous JAM alert
Maintenance
Maintenance timing detection
Service call
When Service Call key is pressed.
Toner send request
When toner order auto send setting reaches.
Toner collect request
Toner installation data revision. However, only
for a new product.
Alert resend
0
A:
A
1
B
0
; FUNCTION(0:YES 1:NO)
㧧
ALERT(0:YES 1:NO)
SIMULATION NO.27-07
FSS FUNCTION SETUP (FUNCTION)
1
[ 0~ 1 ]
OK
TEST
CLOSE
Item
Display
Content
Setting
range
Default
value
A
FEED TIME1
Threshold value of paper
feed time between sensors
(Main unit)
0 to 100
50 (%)
B
FEED TIME2
Threshold value of paper
feed time between sensors
(SPF)
0 to 100
50 (%)
C
GAIN
ADJUSTMENT
RETRY
Threshold value of gain
adjustment retry number
1 to 100
50
(TIMES)
D
JAM ALERT
Threshold value of
continuous JAM alert
judgment
1 to 100
10
(TIMES)
0
A:
A
㧦
50
㧧
FEED
TIME1
B
㧦
50
㧧
FEED
TIME2
SIMULATION
NO.27-09
FSS
FUNCTION
ADJUSTMENT
50
㨇
0
㨪
100
㨉
OK
TEST
CLOSE
C
㧦
50
㧧
GAIN
ADJUSTMENT
RETRY
D
㧦
50
㧧
JAM
ALERT