MX-2300/2700 N/G SIMULATION 7 – 64
<Display item and content of each item>
* When the display item is not executed yet, “–––” is displayed. In case of an error, “ERR” is displayed.
* An error display is not made for the reference value and the correction value, and the previous value is displayed.
44-56
Purpose
: Setting
Function (Purpose)
: (This function is not used. Do not operate.)
Used to perform the forcible execution of 1
pixel half tone correction.
Section
: Process
Item
: Operation
Operation/Procedure
1)
When the machine enters Simulation 44-56, the following
screen is displayed.
When [EXECUTE] button is pressed, the forcible execution of
1 pixel process control is started. (When [EXECUTE] button is
pressed during execution, the operation is interrupted.)
* In case of a sensor adjustment error, press [EXECUTE] but-
ton to resume the operation.
2)
The display shifts to the normal completion screen or the error
screen automatically.
When [RESULT] button is pressed, the result screen is dis-
played.
* Select a color with [K] [C] [M] [Y] buttons. The data of the
selected color are displayed.
Only one color button can be selected. The selected button
is highlighted. (In the initial screen, black ([K]) is selected.)
* When [EXECUTE] button is pressed, the 1 pixel process
control correction value setting is performed again.
<Result display and content description>
44-57
Purpose
: Data clear
Function (Purpose)
: (This function is not used. Do not operate.)
Used to clear the correction value of 1 pixel
half tone correction.
Section
: Process
Item
: Data clear
Operation/Procedure
1)
Press [EXECUTE] button.
[EXECUTE] button is highlighted, and [YES] and [NO] buttons
becomes active display.
2)
Press [YES] button.
* The half tone correction value is cleared. [YES] button is
highlighted.
* When [NO] button or [EXECUTE] button is pressed, [EXE-
CUTE] button returns to the normal display, and [YES] and
[NO] buttons gray out.
* After completion of clearing the half tone correction value,
[EXECUTE] button returns to the normal display, and [YES]
and [NO] buttons gray out.
* The cleared data are saved to EEPROM and RAM.
<Half tone correction value clear item>
Category
Page number
Display item
Content
Display range
Approximation
result
1/2
[EX-LOW]
EXTRA lowest density area approximation formula
coefficient
A: –10.000 to +10.000
B: –255.000 to +255.000
[LOW]
Low density approximation formula coefficient
A: –10.000 to +10.000
B, C:-255.000 to +255.000
[CONNECT]
Approximation formula coefficient when connecting low
density and middle density
A: –10.000 to +10.000
B: –255.000 to +255.000
[MID]
Middle density approximation formula coefficient
A: –10.000 to +10.000
B, C: –255.000 to +255.000
2/2
[HIGH]
High density approximation formula coefficient
A: –10.000 to +10.000
B: –255.000 to +255.000
[CONNECT SENSOR]
Sensor output at connecting point of each density area
#1 to #4: 0 to 255
Reference
register value
1/1
[SENSOR_TARGET]
Reference value registration value of each color and each
point of 1 pixel half tone correction
#1 to #15
Correction value
1/1
[S_VALUE]
Correction value of each color and each point of 1 pixel
half tone correction
#1 to #15
Display
Content
COMPLETE
Normal completion
INTERRUPTION
Forcible interruption
CL_SEN_ADJ_ERR
Color sensor adjustment error
BK_SEN_ADJ_ERR
Black sensor adjustment error
[YMCK]
High density process control [YMCK] error
CONNECTION_ERR
Connection error
K
M
Y
C
SIMULATION
NO.44
㧙
54
TEST
1 PIXEL HALF TONE RESULT DISPLAY
CLOSE
[EX-LOW]
A: 01.000
,
B: 100.000
[LOW]
A: -10.000
,
B: -200.000
, C: 200.000
[CONNECT] A:
10.000
,
B: -150.000
[MID]
A:
05.000
,
B: 200.000
,
C: 150.000
1/2
NEXT
0
Half tone correction value clear item
1 to 15
Process control half tone correction value
SIMULATION
NO.44
̆
56
TEST
1PIXEL
HALF TONE DENSITY CORRECT EXECUTION
EXECUTE
0
CLOSE
TOUGH [EXECUTE] THEN EXECUTION START.
0
SIMULATION
NO.44
̆
57
TEST
1
PIXEL
HALF
TONE ADJUSTMENT DATA CLEAR
CLOSE
EXECUTE
ARE YOU SURE?
YES
NO