MX-2300/2700 N/G SIMULATION 7 – 94
If there is any item under [
↓
], an active display is made and
item is shifted.
If there is no item over [
↓
], the display grays out and the
operation is invalid.
2)
Enter the set value with 10-key.
* Press [C] key to clear the entered values.
3)
When [OK], [
↑
], [
↓
] button, [COLOR], or [BLACK] key is
pressed, it is highlighted and the currently entered data are
saved to EEPROM and RAM.
* When [CLOSE] button is pressed, the display is shifted to the
copy basic screen of simulation.
* Copying can be performed also by pressing [COLOR]/[BLACK]
key.
<Set range and default value of each setup>
A,B: The greater the value is, the slower the scan timing is.
The greater the adjustment values of C to H are, the greater the
image loss is.
A to H: 1 step = 0.1 m
The RSPF rear edge image loss is provided against shade.
50-7
Purpose
: Adjustment
Function (Purpose)
: Used to adjust the copy image position on
print paper in the copy mode and to adjust
the void area (image loss). (The similar
adjustment can be executed with SIM50-6
(Simple type).) (RSPF mode)
Section
: RSPF
Item
: Image quality
Operation/Procedure
1)
In advance, execute the SPF sub scanning direction magnifi-
cation ratio (SIM48-01).
2)
Select the set item with [
↑
] and [
↓
] buttons.
The highlighted section is and the value is displayed in the set-
ting area.
* If there is any item over [
↑
], an active display is made and
item is shifted.
If there is no item over [
↑
], the display grays out and the
operation is invalid.
If there is any item under [
↓
], an active display is made and
item is shifted.
If there is no item over [
↓
], the display grays out and the
operation is invalid.
3)
Set L4 and L5 to 0.
When the values of L4 and L5 are changed to 0, the following
adjustment values are automatically set.
Adjustment values of SIDE1, 2: 50
After completion of calculation, the value of L4/L5 returns to 0.
4)
Set the magnification ratio to 200%, and press [COLOR] or
[BLAC] key to make a copy.
5)
Measure the copied image, and enter the measure value of
distance A (RSPF) to L4 and L5 in the unit of 0.1mm.
L4 : Distance A (SPF front surface: 200%) (Unit: 0.1mm)
L5 : Distance A (SPF back surface: 200%) (Unit: 0.1mm)
* When [CLOSE] button is pressed, the display is shifted to the
copy basic screen of simulation.
* Copying can be performed also by pressing [COLOR]/[BLACK]
key.
Item
Display item
Description
Set
range
Default
value
A
SIDE1
Front surface
document
scan start
position
adjustment
(CCD)
1 to 99
50
B
SIDE2
Back surface
document
scan start
position
adjustment
(CCD)
1 to 99
50
C
Image
loss
quantity
setting
SIDE1
LEAD_EDGE
(SIDE1)
Front surface
image loss
quantity
setting
0 to 99
20
D
FRONT_REAR
(SIDE1)
Front surface
side image
loss quantity
setting
0 to 99
20
E
TRAIL_EDGE
(SIDE1)
Front surface
rear edge
image loss
quantity
adjustment
0 to 99
30
F
Image
loss
quantity
setting
SIDE2
LEAD_EDGE
(SIDE2)
Back surface
image loss
quantity
setting
0 to 99
20
G
FRONT_REAR
(SIDE2)
Back surface
side image
loss quantity
setting
0 to 99
20
H
TRAIL_EDGE
(SIDE2)
Back surface
rear edge
image loss
quantity
adjustment
0 to 99
30
0
A:
A : 50
;
SIDE1
B : 50
;
SIDE2
C : 20
;
LEAD EDGE
D : 20
;
FRONT_REAR
SIMULATION NO.50-06
LEAD EDGE ADJUSTMENT VALUE(SPF)
50
[
1~
99 ]
TEST
CLOSE
OK
Distance A