MX-2300/2700 N/G SIMULATION 7 – 52
<Operation content>
1)
Adjust so that the LED light emitting quantity of BK/CL is the
target value
±
2.
* Target value
BK: Item B of SIM 44-04
CL: Item A of SIM 44-13
2)
After completion of the adjustment, check the belt surface con-
dition with the BK sensor.
<Set range and default value of each fusing temperature setting>
<List of errors>
44-4
Purpose
: Setting
Function (Purpose)
: Used to perform the correction operation of
the image forming section and to set the
process control sensor adjustment condi-
tions.
Section
: Process
Item
: Operation
Operation/Procedure
NOTE: Unless a special change is required, set the set values to
the default values.
1)
Select the set item with [
↑
] and [
↓
] buttons.
The highlighted set value is switched and the value is dis-
played in the setting area.
* If there is any item over [
↑
], an active display is made and
item is shifted.
If there is no item over [
↑
], the display grays out and the
operation is invalid.
If there is any item under [
↓
], an active display is made and
item is shifted.
If there is no item over [
↓
], the display grays out and the
operation is invalid.
2)
Enter the set value with 10-key.
* Press [C] key to clear the entered values.
When setting is completed, [OK] button returns to the normal
display.
Classification
Item
Display item
Content
Set range
Default value
Save
PROCON
A
PCS_CL LED ADJ
Color sensor light emitting quantity adjustment value
1 to 255
21
YES
B
PCS_K LED ADJ
Black sensor light emitting quantity adjustment value
1 to 255
21
YES
C
PCS_CL DARK
Color dark voltage
0 to 255
0
NO
D
PCS_K DARK
Black dark voltage
0 to 255
0
NO
E
PCS_K GRND
Belt surface when item B adjustment is completed.
0 to 255
0
NO
F
PCS_K BELT MAX
Belt surface input max. value
0 to 255
0
NO
G
PCS_K BELT MIN
Belt surface input min. value
0 to 255
0
NO
H
PCS_K BELT DIF
Belt surface input difference (Item E – Item F)
0 to 255
0
NO
REGIST
I
REG_F LED ADJ
Registration sensor light emitting quantity adjustment value F
1 to 255
56
YES
J
REG_R LED ADJ
Registration sensor light emitting quantity adjustment value R
1 to 255
56
YES
K
REG_F DARK
Registration sensor dark voltage F
0 to 255
0
NO
L
REG_R DARK
Registration sensor dark voltage R
0 to 255
0
NO
M
REG_F GRND
Belt surface when completion of Item I adjustment
0 to 255
0
NO
N
REG_R GRND
Belt surface when completion of Item J adjustment
0 to 256
0
NO
O
REG_F BELT MAX
Belt surface input max. value (Front side)
0 to 255
0
NO
P
REG_F BELT MIN
Belt surface input min. value (Front side)
0 to 255
0
NO
Q
REG_F BELT DIF
Belt surface input difference (Item O – Item P)
0 to 255
0
NO
R
REG_R BELT MAX
Belt surface input max. value (Rear side)
0 to 255
0
NO
S
REG_R BELT MIN
Belt surface input min. value (Rear side)
0 to 255
0
NO
T
REG_R BELT DIF
Belt surface input difference (Item R – Item S)
0 to 255
0
NO
U
REG_F PATCH (K)
Patch light receiving potential F (K)
0 to 255
0
YES
V
REG_F PATCH (C)
Patch light receiving potential F (C)
0 to 255
0
YES
REGIST
W
REG_F PATCH (M)
Patch light receiving potential F (M)
0 to 255
0
YES
X
REG_F PATCH (Y)
Patch light receiving potential F (Y)
0 to 255
0
YES
Y
REG_R PATCH (K)
Patch light receiving potential R (K)
0 to 255
0
YES
Z
REG_R PATCH (C)
Patch light receiving potential R (C)
0 to 255
0
YES
AA
REG_R PATCH (M)
Patch light receiving potential R (M)
0 to 255
0
YES
AB
REG_R PATCH (Y)
Patch light receiving potential R (Y)
0 to 255
0
YES
Error name
Error content
Black sensor
adjustment error
→
PCS_K LED ADJ error, retry in 3 times, target
not reached
Color sensor
adjustment error
→
PCS_CL LED ADJ error, retry in 3 times,
target not reached
Surface read error
→
PCS_K GRND error, belt 1 lap, outside the
range of effective difference between upper and
lower values
Registration sensor F
adjustment error
→
REG_F LED ADJ error, retry in 3 times, target
not reached
Registration sensor R
adjustment error
→
REG_R LED ADJ error, retry in 3 times, target
not reached
Registration surface F
read error
→
REG_F GRND error, belt 1 lap, outside the
range of effective difference between upper and
lower values
Registration surface R
read error
→
REG_R GRND error, belt 1 lap, outside the
range of effective difference between upper and
lower values
0
SIMULATION NO.44-02
TEST
PROCON GAIN ADJUSTMENT
EXECUTE
PCS_CL LED ADJ
21
:
PCS_K GRND
0
:
PCS_K LED ADJ
21
:
PCS_K BELT MAX
0
:
PCS_CL DARK
0
:
PCS_K BELT MIN
0
:
PCS_K DARK
0
:
PCS_K BELT DIF
0
:
1/4
CLOSE