MX-2300/2700 N/G SIMULATION 7 – 50
43-24
Purpose
: Setting
Function (Purpose)
: Used to enter the correction values for SIM
43-1 and SIM 43-4 temperature correc-
tions.
Section
: Fusing
Item
: Operation
Operation/Procedure
1)
Select the set item with [
↑
] and [
↓
] buttons.
The highlighted section of the set value is switched and dis-
played on the set setting area.
* If there is any item over [
↑
], an active display is made and
item is shifted.
If there is no item over [
↑
], the display grays out and the
operation is invalid.
If there is any item under [
↓
], an active display is made and
item is shifted.
If there is no item over [
↓
], the display grays out and the
operation is invalid.
2)
Enter the set value with 10-key.
* Press [C] key to clear the entered values.
3)
When [OK], [
↑
], [
↓
] button, [COLOR], or [BLACK] key is
pressed, the entered value is set.
* Input value: The intercept for the correction value is 50. This is
because the set value is kept as a positive number in case of a
negative setting due to negative correction.
• Set value: Value to be set (–49 to +49)
Input value: Actual input value (1 to 99)
<Set range and default value of each setup>
* On adjustment values
Each temperature correction value
→
Temperature 1
°
C change
by 1 count
Each paper exit count
→
1 sheet by 1 count
Each cool-down time
→
1s change by 1 count
<Code descriptions of the above list>
Set value
–49
–25
–5
0
+5
+25
+49
Input value
1
25
45
50
55
75
99
Item
Display items
Item descriptions
Set
range
Default
value
A
NN_120_ WUP_HL_UM & HL_US
WARMUP end temperature
correction value
120
°
C or below when turning
on the power under NN
environment
Common to items
HL_UM, HL_US
1 to 99
50
B
NN_120_WUP_HL_LM
Item HL_LM
1 to 99
50
C
LL_120_WUP_HL_UM & HL_US
120
°
C or below when turning
on the power under LL
environment
Common to items
HL_UM, HL_US
1 to 99
50
D
LL_120_WUP_HL_LM
Item HL_LM
1 to 99
50
E
HH_120_WUP_HL_UM & HL_US
120
°
C or below when turning
on the power under HH
environment
Common to items
HL_UM, HL_US
1 to 99
50
F
HH_120_WUP_HL_LM
Item HL_LM
1 to 99
50
G
ON_120_WUP_HL_UM
Temperature correction value
immediately after completion of
warm-up and during continuation
of temperature correction
120
°
C or below when turning
on the power
Item HL_UM
1 to 99
40
H
ON 120 WUP HL_US
Item HL_US
1 to 99
55
I
NN_120_ FUS_DUP_HL_UM & HL_US
Fusing temperature correction
value
120
°
C or below when turning
on the power under NN
environment
Common to items
HL_UM, HL_US
1 to 99
55
J
NN_120_ FUS_DUP_HL_LM
Item HL_LM
1 to 99
50
K
LL_120_ FUS_DUP_HL_UM & HL_US
120
°
C or below when turning
on the power under LL
environment
Common to items
HL_UM, HL_US
1 to 99
60
L
LL_120_ FUS_DUP_HL_LM
Item HL_LM
1 to 99
50
M
HH_120_ FUS_DUP_HL_UM & HL_US
120
°
C or below when turning
on the power under HH
environment
Common to items
HL_UM, HL_US
1 to 99
50
N
HH_120_ FUS_DUP_HL_LM
Item HL_LM
1 to 99
50
O
NN_120_ FUS_DUP_CNT
Fusing duplex paper exit count
Under NN environment
1 to 60
5
P
LL_120_ FUS_DUP_CNT
Under LL environment
1 to 60
10
Q
HH_120_ FUS_DUP_CNT
Under HH environment
1 to 60
5
R
COOL_DOWN_HEAVY
Cool-down time
Heavy paper
1 to 60
15
S
COOL_DOWN_OHP
OHP
1 to 60
30
T
COOL_DOWN_DEVELOP
Envelope
1 to 60
40
U
WUP DUP TIME
Temperature correction
continuation time immediately
after completion of warm-up
-
0 to 255
90
TH_UM
Fusing upper thermister MAIN center
TH_LM
Fusing lower thermister MAIN
TH_US
Fusing upper thermister SUB edge
HL_UM
Heater lamp upper MAIN
HL_LM
Heater lamp lower MAIN
HL_US
Heater lamp upper SUB
0
A:
A : 50
B : 50
C : 50
D : 50
NN_120_WUP_HL_UM&HL_US
NN_120_WUP_HL_LM
LL_120_WUP_HL_UM
㧒
HL_US
LL_120_WUP_HL_LM
SIMULATION NO.43-24
FUSER TEMP RESET
50
㨇
1
㨪
99
㨉
OK
TEST
CLOSE