MX-2300/2700 N/G ADJUSTMENTS 6 – 62
5)
Press [EXCUTE] key.
The adjustment pattern is printed out.
6)
Set the adjustment pattern on the document table. (Any direc-
tion)
Note: Fit the adjustment pattern correctly with the document
guide.
7)
Press [EXCUTE] key.
The following items are automatically adjusted.
* Print image lead edge image position adjustment
* Print image off-center adjustment
8)
Press [OK] key.
The adjustment result becomes valid.
Perform procedures 4) to 7) for each paper feed tray.
27-C Copy lead edge image reference position
adjustment, image off-center, sub scanning
direction image magnification ratio auto-
matic adjustment
1)
Enter the SIM50-28 mode.
2)
Select [OC ADJ] with the key button.
3)
Select the paper feed tray with paper in it with the key button.
(Any paper size will do.)
4)
Press [EXCUTE] key.
The adjustment pattern is printed out.
5)
Set the adjustment pattern on the document table. (Any direc-
tion)
Note: Fit the adjustment pattern correctly with the document
guide.
6)
Press [EXCUTE] key.
The following items are automatically adjusted.
Copy lead edge image reference position adjustment,
image off-center, sub scanning direction image magnifica-
tion ratio automatic adjustment
7)
Press [OK] key.
The adjustment result becomes valid.
27-D SPF mode image off-center, image lead
edge position, sub scanning direction
image magnification ratio automatic adjust-
ment
Refer to the RSPF (MX-RPX1) SM.
SIMULATION NO.50-28
TEST
AUTO IMAGE POSITION ADJUSTMENT : SERVICE
OC ADJ
BK-MAG ADJ
SPF ADJ
SETUP/PRINT ADJ
RESULT
DATA
1/1
0
CLOSE
0
SIMULATION
NO.50-28
TEST
AUTO
IMAGE
POSITION
ADJUSTMENT
㧦
SERVICE
EXECUTE
1/1
MFT
CS1
CS2
CLOSE
0
SIMULATION NO.50-28
TEST
AUTO
IMAGE
POSITION
ADJUSTMENT
SERVICE
CLOSE
EXECUTE
PLEASE
SET
THE
SIT
CHART
PAPER
ON
THE
OC
THEN
PRESS
[EXECUTE]
TO
START
REPRINT
0
SIMULATION NO.50-28
TEST
AUTO
IMAGE
POSITION
ADJUSTMENT
SERVICE
CLOSE
OC
LEAD
OFFSET
SUB
RESCAN
REPRINT
OK
RETRY
DATA