MX-2300/2700 N/G SIMULATION 7 – 59
* When [NEXT] button is pressed, the data of the next cate-
gory are displayed regardless of the display page.
* When [CLOSE] button is pressed, the display shifts to the copy
basic screen of simulation.
* Copying can be performed also by pressing [COLOR]/[BLACK]
key.
<Display item and content of each category>
* When the display item is not executed yet, “–––” is displayed. In
case of an error, "ERR" is displayed.
* An error display is not made for the reference value and the cor-
rection value, and the previous value is displayed.
44-25
Purpose
: Adjustment/Setup/Operation data output/
Check (Display/Print)
Function (Purpose)
: Used to check the initial condition of pro-
cess control (half tone correction).
Section
: Process
Item
: Data (Machine condition)
Operation/Procedure
1)
Select a color with [K] [C] [M] [Y] buttons. (In this example, [K]
is selected.) The data of the selected color are displayed.
* Only one color button can be selected. The selected button
is highlighted. (In the initial screen, black ([K]) is selected.)
2)
Select the set item with [
↑
] and [
↓
] buttons.
The highlighted set value is switched and the value is dis-
played in the setting area.
* If there is any item over [
↑
], an active display is made and
item is shifted.
If there is no item over [
↑
], the display grays out and the
operation is invalid.
If there is any item under [
↓
], an active display is made and
item is shifted.
If there is no item over [
↓
], the display grays out and the
operation is invalid.
3)
Enter the set value with 10-key.
* Press [C] key to clear the entered values.
4)
When [OK] button is pressed, it is highlighted and the current
set data are saved to EEPROM and RAM.
* Also when [OK], [
↑
], [
↓
], [COLOR], or [BLACK] key is
pressed, the current set value is saved to EEPROM and
RAM.
<Set range of each set value>
Category
Page
number
Display item
Content
Coefficient
1/2
[RIZE]
Low density rising point
[SATURATE]
High density saturation
point
[STEP]
(Saturation pint – Rising
point) / 10
[EX-LOW]
Coefficient of the
approximation formula
of lowest density
[LOW]
Coefficient of the
approximation formula
of low density
[CONNECT]
Coefficient of the
approximation formula
when connecting low
density and middle
density
2/2
[MID]
Coefficient of the
approximation formula
of middle density
[HIGH]
Coefficient of the
approximation formula
of high density
[CONNECT POINT]
Density sections
connection output ratio
Reference
value
1/1
[SENSOR_TARGET]
Half tone process
control reference value
Correction
value
1/1
[S_VALUE]
Half tone process
control correction
amount
For printer
1/3
[PRINTER_S_VALUE]
Printer half tone
process control
correction value
2/3
[PRINTER_BASE_DI
THER_VALUE]
Printer half tone
process control
reference dither value
3/3
[PRINTER_AUTO_HT
_VALUE]
Printer auto density
adjustment correction
value
K
M
Y
C
SIMULATION
NO.44
㧙
24
TEST
HALF TONE PROCON RESULT DISPLAY
CLOSE
[RIZE] 16
[SATURATE] 109
[STEP] 9.3
[EX-LOW]
A:
0.0
,
B: 100.0
[LOW]
A:- 0.013
,
B:-
0.569
, C: 107.444
[CONNECT] A:
0.0
,
B:
0.0
1/2
NEXT
0
Item
Display
Set
range
Content
Default
value
A
1ST PATCH
0 to 255
Half tone process control
1ST step 1st patch print
gradation
40
B
2ND PATCH
0 to 255
Half tone process control
1ST step 2nd patch print
gradation
60
C
3RD PATCH
0 to 255
Half tone process control
1ST step 3rd patch print
gradation
80
D
4TH PATCH
0 to 255
Half tone process control
1ST step 4th patch print
gradation
100
E
5TH PATCH
0 to 255
Half tone process control
1ST step 5th patch print
gradation
255
A:
A 40
B 60
C 80
D 100
1ST PATCH
2ND PATCH
3RD PATCH
4TH PATCH
SIMULATION NO.44-25
HALF TONE PROCON INITIAL VALUE DISPLAY
40
0
255
OK
TEST
K
C
M
Y
0
CLOSE