Fault table CiA402 profile
Operating Instructions – MOVIMOT
®
flexible
293
8.7.18
Fault 23 Power section
Subfault: 23.1
Description: Warning
Response: Warning with self-reset
Cause
Measure
Power section fault with fault response of the type
"warning".
See also "Power section subcomponent" fault
status.
Subfault: 23.2
Description: Fault
Response: Emergency stop + output stage inhibit
Cause
Measure
Power section fault with fault response of the type
"standard".
See also "Power section subcomponent" fault
status.
Subfault: 23.3
Description: Critical fault
Response: Output stage inhibit
Cause
Measure
Power section fault with fault response of the type
"critical fault".
See also "Power section subcomponent" fault
status.
Subfault: 23.4
Description: Hardware fault
Response: Output stage inhibit
Cause
Measure
A fault occurred in a hardware component of the
power section, e.g.: Overcurrent hardware com-
parator.
– Check the current supply.
– Increase the ramp time.
– Check for correct motor size (the motor current
is too high).
– Contact SEW-EURODRIVE Service.
Switched-mode power supply fault, hardware
fault.
– Check the current supply.
– Check the DC 24 V supply voltage.
Fault at the gate driver of an IGBT.
Defect in the power output stage. Contact
SEW‑EURODRIVE Service.
Invalid process data configuration. Status of con-
trol section and power section are not compatible.
Contact SEW-EURODRIVE Service.
Subfault: 23.5
Description: Invalid process data configuration
Response: Output stage inhibit
Cause
Measure
Invalid process data configuration.
Contact SEW-EURODRIVE Service.