Subfault: 16.24
Description: Speed controller sampling cycle not possible with current PWM frequency or current
control mode
Response: Application stop + output stage inhibit
Cause
Measure
At a PWM frequency of "2.5 kHz", only the speed
controller sampling cycle of 2 ms is permitted. For
ELSM
®
control mode, the only permitted speed
controller sampling cycles are 1 ms and 2 ms.
Increase the PWM frequency or increase the
sampling cycle of the speed controller to 2 ms.
For ELSM
®
control mode, set the sampling cycle
to 1 ms or 2 ms.
Subfault: 16.25
Description: User-defined current limit too low for standstill current
Response: Output stage inhibit
Cause
Measure
User-defined current limit value too small for min-
imum standstill current.
Increase the user-defined current limit, or disable
the standstill current function.
Subfault: 16.26
Description: Nominal values incomplete or implausible
Response: Output stage inhibit
Cause
Measure
During startup using nameplate data: Nominal
voltage, nominal current, nominal speed or nom-
inal torque are not entered or are not plausible.
Enter or check nominal voltage, nominal current,
nominal speed, and nominal torque.
Subfault: 16.27
Description: Maximum current or maximum torque not plausible
Response: Output stage inhibit
Cause
Measure
During startup using nameplate data: Maximum
current or maximum torque not entered, or maxi-
mum current and maximum torque not plausible.
Check the maximum current and maximum
torque.
Subfault: 16.30
Description: Faulty EtherCAT
®
EEPROM configuration status
Response: Warning
Cause
Measure
The configuration status of the EtherCAT
®
/
SBus
PLUS
EEPROM is faulty.
EEPROM not loaded, binary file not loaded.
Contact SEW-EURODRIVE Service.
Faulty EEPROM loading procedure.
Contact SEW-EURODRIVE Service.
Faulty EEPROM checksum.
Contact SEW-EURODRIVE Service.
29128668/EN – 12/2019