5
Electrical installation
Plug connector assignment at the electronics cover
Operating Instructions – MOVIMOT
®
flexible
138
5.12
Plug connector assignment at the electronics cover
5.12.1
X5133_1: Digital inputs
The following table shows information about this connection:
Function
Digital inputs
Connection type
M12, 5‑pin, female, A‑coded, color: black
Connection diagram
1
4
3
2
5
Assignment
Contact
Signal
Description
1
+24V
DC 24 V sensor supply
2
DI02
Sensor input DI02
3
0V24
0V24 reference potential for sensors
4
DI01
Sensor input DI01
5
FE
Functional earth
29128668/EN – 12/2019