6
Startup
DIP switch
Operating Instructions – MOVIMOT
®
flexible
161
DIP switch S2
The following table shows the functions of DIP switch S2:
DIP switch
S2
1
2
3
4
Binary coding EtherCAT
®
device ID
Bit 2
4
Bit 2
5
Bit 2
6
Bit 2
7
ON
1
1
1
1
OFF
0
0
0
0
DIP switch S3
Use the DIP switch S3 for starting up the drive train for motors without digital interface.
Motor assignment depends on the nominal output current of the electronics cover via
the DIP switches S3/3 and S3/4.
Startup via DIP switch S3 is only effective if the following requirements are met when
using the memory module:
•
The drive train has not been started up using MOVISUITE
®
or CBG...
•
The drive train has not been started up via digital interface (DDI).
•
The connected motor does not have a digital interface (DDI), and the connection
unit of MOVIMOT
®
flexible has the option /DI.
The following table shows the functions of DIP switch S3:
DIP switch
S3
1
2
3
4
5
6
7
8
9
10
Meaning
Brake
type
Motor
connec-
tion type
1)
Binary coding
Motor assign-
ment
Motor protec-
tion
Motor series
2
0
2
1
2
0
2
1
2
0
2
1
2
2
2
3
ON
Optional
brake
m
1
1
1
1
1
1
1
1
OFF
Standard
brake
W
0
0
0
0
0
0
0
0
1) If the motor connection type is changed via DIP switch S3/2, the motor connection type via DIP switch D3/3 and S3/4 must be
checked and adapted if necessary.
29128668/EN – 12/2019