5
Electrical installation
Assignment of the optional plug connectors
Operating Instructions – MOVIMOT
®
flexible
109
5.11.6
X2313: DC 24 V output backup voltage
The following table shows information about this connection:
Function
DC 24 V output backup voltage
Connection type
M12, 5‑pin, female, L‑coded, color: light gray
Connection diagram
4
1
3
2
Assignment
Contact
Signal
Description
1
+24V/L1
DC 24 V output/L1
(for backup mode)
2
0V24/N2
0V24 reference potential/N2
(for DC 24 V /BES brake rectifier)
3
0V24/N1
0V24 reference potential/N1
(for backup mode)
4
+24V/L2
DC 24 V connection/L2
(for DC 24 V /BES brake rectifier)
FE
Functional earth
29128668/EN – 12/2019