Commissioning
PR5230 Instrument Manual
EN-124
Sartorius
5.7.2.2
Configuring Inputs
An action both for signal change from 0 to 1 (on) and from 1 to 0 (off) can be determined for each of the three
inputs. The action may be dependent on another condition which must be met.
Setup/
Digital I/O parameter
Output 1
marker bit 1
X64=1
Output 2
marker bit 2
X65=1
Output 3
marker bit 3
X66=1
Input 1 on
set tare
X113=1
Condition no
condition
-----
Input 1 off
-no action-
Input 2 on
-no action-
Input 2 off
-no action-
Input 3 on
-no action-
Input 3 off
-no action-
1. Determining an action
Determine the action for the rising edge of input 1 under [Input 1 on] from the following list (here: When the
input signal changes from 0 to 1, a tare command is generated).
Accordingly, an action for the falling edge can be determined.
Selection list for actions of the inputs [Input 1/2/3 on/off]
Function
SPM Bit
-no action-
-----
No function
set marker 1
X64=1
Set marker 1
set marker 2
X65=1
Set marker 2
set marker 3
X66=1
Set marker 3
select net
X72=1
Select net
set zero
X112=1
Set zero
set tare
X113=1
Set tare
reset tare
X114=1
Reset tare
set test
X115=1
Activate the analog test
reset test
X116=1
Finish the analog test
reset PWF
X117=1
Reset power fail
set fixtare
X118=1
Set fixtare (use the value in address D31 as a tare value)
get fixtare
X119=1
Save gross value as fixtare in address D31
set print
X120=1
Activate a print order
clr marker 1
X64=0
Clear marker 1
clr marker 2
X65=0
Clear marker 2
clr marker 3
X66=0
Clear marker 3
select gross
X72=0
Save the gross weight in address D11