Specifications
3
English
219
Terminal board specifications
Input/output terminals
Signal level
Input/output circuit
Alarm input
[No-volt contacts]
Sensor alarm output
[Open collector/1k
Ω
, Low
level active (max: 25mA)]
CTL4,5 Remote control input
[Two-wire voltage control]
(
J
P.17)
CTL6 Clock adjust input
[No-volt contacts]
CTL7 Clock adjust output
[Normal 5V/5.7k
Ω
, Low level
active]
CTL8 External timer input
[No-volt contacts]
CTL9 Alarm output
[Open collector/1k
Ω
, Low
level active (max: 500mA)]
0V
Open
ground
input
100ms or more
10k
100k
5V
IC
74HC597
Terminal
0V
Open
Detect motion
sensor
Stop alarm
recording
1k
IC
BU209
Terminal
1k
+5V
4.7k
Remote
control
terminal
Sub micro
processor
0V
Open
ground
input
100ms or more
10k
100k
5V
1k
IC
74HC597
Terminal
0V
5V
Approx. 1 second
1k
4.7k
5V
IC
BU209
Terminal
0V
Open
ground
input
100ms or more
10k
100k
5V
1k
IC
74HC597
Terminal
0V
Open
Start alarm
recording
Finish alarm
recording
4.7k
5V
4.7k
12V
IC
BU209
Terminal