RECORD SET
2
English
99
5
Turn the jog dial to select an alarm
detection method and then turn the
shuttle dial clockwise.
The cursor moves to “MOTION SENSOR”.
[Settings] (
indicates default setting)
*1 External alarm
z
Switch is attached to the ALARM IN terminal on the rear
panel and alarm is detected by opening and closing the
switch.
z
Coaxial alarm signals from a coaxial superimposition
camera
[Setting conditions]
z
When “SENSOR”, “ALARM AND SENSOR” or “ALARM
OR SENSOR” is selected, the motion sensors must be set.
6
Press the [EXIT/OSD] button.
The setting is completed and the display returns to the normal
screen.
Use the following procedure to set motion sensors on video
from each camera so that alarms can be detected.
(1) Motion sensor setting
Display changes in response to the sensor condition. Settings
are made using the jog dial.
-: Sensor off
A or B: Sensor on
(2) Camera number display
Changes when a [CAMERA SELECT] button is pressed. Use
this item to select the camera for which motion sensors are to
be set up.
(3) Time period
Select an interval set using “TIME PERIOD” (
J
P.69).
(4) LEVEL
Sets the sensitivity level of the motion sensors.
OFF: No motion sensor has been set.
1 to 10: A motion sensor is set. Lower values correspond to
higher sensitivity levels and vice versa.
(5) MODE
Sets the detection method for the motion sensors. (
J
P.102)
1
Make timer settings for “TIME PERIOD
A” and “TIME PERIOD B” on the <TIME
PERIOD SET> screen. (
J
P.69)
2
Press the [MENU] button.
The MENU indicator lights up and the <MAIN MENU> is
displayed.
Setting
Description
ALARM
Alarm recording is performed when
an external alarm
*1
occurs.
SENSOR
Alarm recording is performed when
a motion sensor detects movement.
(
J
P.99)
ALARM AND SENSOR
Alarm recording is performed when
both the external alarm
*1
and a
motion sensor are activated
simultaneously.
ALARM OR SENSOR
Alarm recording is performed when
either the external alarm
*1
or a
motion sensor is activated.
<ALARM REC MODE SET>
ALARM RECORDING : ENABLED
PICTURE QUALITY : ENHANCED
PICTURE QUALITY SET ->
AUDIO RECORDING : OFF
ALARM INTERLEAVE : ONLY
REC RATE: 15FPS, DURATION: 20SEC
PRE-ALARM RECORDING : OFF
REC RATE: ***** FPS, DURATION: *****
ALARM TRIGGER : ALARM
MOTION SENSOR ->
EXIT/OSD
Setting the motion sensors
CH01 T-1 LEVEL : OFF MODE : A
(1)
(2)
(3)
(4)
(5)
MENU
e00_l8hbd_us_7.book Page 99 Thursday, March 31, 2005 5:49 PM