2. Specifications
2-17
■
Specifications
Speed control range
1: 5000 Note 2)
Frequency characteristics
2200Hz Note 3)
Allowable load inertia moment
10 times motor rotor inertia moment Note 4)
Note 2) Internal speed command
Note 3) In case of high-velocity sampling mode
Note 4) When the value exceeds the above allowable load inertia moment, please contact us.
■
Built-in functions (100/200 VAC, 400 VAC)
Protection functions
Over current, Current detection error, Overload, Regeneration error, Overheat
error, External overheating, Over voltage, Main circuit power low voltage, Main
circuit power supply open phase, Control power supply low voltage, Encoder
error, Over speed, Speed control error, Speed feedback error, Excessive position
deviation, Position command pulse error, Built-in memory error, Parameter error,
Cooling fan error
Digital operator
Status display, Monitor display, Alarm display, Test operation
Dynamic brake circuit
Built-in Note 5)
Regeneration process circuit
Built-in Note 6)
Monitor
Speed monitor (VMON)
2.0 V±10 % (at 1,000 min
-1
)
Torque (Thrust) (TCMON)
2.0 V±10 % (at 100 %)
Note 5) For RS3C30, just DB signal output circuit is built in.
Note 6) For RS3C15/30, regenerative resistor is external type only.
■
Built-in functions (Power unit/Amplifier unit combination of 200 VAC-600 A, 400 VAC-800 A)
Protection functions
Over current, Current detection error, Overload, Regeneration error, Overheat
error, External overheating, Over voltage, Main circuit power low voltage, Main
circuit power supply open phase, Control power supply low voltage, Encoder
error, Over speed, Speed control error, Speed feedback error, Excessive position
deviation, Position command pulse error, Built-in memory error, Parameter error,
Cooling fan error
Digital operator
Status display, Monitor display, Alarm display, Parameter setting,
Test operation, Adjustment mode
Dynamic brake circuit
Not included Note 7)
Regeneration process circuit
Included Note 8)
Monitor
Speed monitor (VMON)
2.0 V±10 % (at 1,000 min
-1
)
Torque (Thrust) (TCMON)
2.0 V±10 % (at 100 %)
Note 7) Only dynamic brake timing signal output circuit is included.
Note 8) Regenerative resistor is attached external.
Summary of Contents for SANMOTION 3E S
Page 1: ...M0011696D Instruction Manual TYPE S For Rotary Motor Linear Motor Interface ...
Page 2: ......
Page 182: ...No Text on This Page ...
Page 200: ...No Text on This Page ...
Page 270: ...No Text on This Page ...
Page 336: ...No Text on This Page ...
Page 384: ...No Text on This Page ...
Page 408: ...No Text on This Page ...
Page 420: ...12 Appendix 12 10 12 4 Servo motor data sheet Refer another document M0011792 ...
Page 422: ...12 Appendix 12 12 12 5 3 RS3 03A HL 12 5 4 RS3A05A HL ...
Page 423: ...12 5 Servo amplifier dimensions 12 13 12 Appendix 12 5 5 RS3A07A HL 12 5 6 RS3A10A HA ...
Page 424: ...12 Appendix 12 14 12 5 7 RS3A15A HA 12 5 8 RS3A30A HL ...
Page 428: ...12 Appendix 12 18 12 5 13 RS3C02A HA 12 5 14 RS3C05A HA ...
Page 429: ...12 5 Servo amplifier dimensions 12 19 12 Appendix 12 5 15 RS3C10A HA 12 5 16 RS3C15A HL ...
Page 430: ...12 Appendix 12 20 12 5 17 RS3C30A HM ...
Page 484: ...12 Appendix 12 74 REGIST 1000W Wiring diagram ...
Page 486: ...No Text on This Page ...
Page 487: ...Release Revision A Sep 2017 Revision B Sep 2018 Revision C Dec 2018 Revision D Apr 2019 ...