8. Maintenance
8-55
- Dedicated to RS3D80# -
■
Alarm Code 62 (Main Circuit Under-voltage)
DC Main circuit low voltage
Corrective
actions
■
Alarm Code 63 (Main Power Supply phase loss)
1 phase of the 3 phase main circuit power supply disconnected
Corrective
actions
Status at the time of alarm
Cause
1
2
3
4
5
Issued when control power is turned ON.
✔
✔
Issued when main circuit power supply is
turned ON.
✔
✔
✔
Issued during operation.
✔
✔
Cause
Investigation and corrective actions
1
■
Input power supply voltage is below
the specified range.
■
Check the power supply and set it
within the specified range.
2
■
Rectifier of main circuit is broken.
■
Replace the power unit.
3
■
Input power supply voltage is
reduced, or instantaneous power
interruption is occurred.
■
Check the power supply, and confirm
that there is no instantaneous power
interruption or low voltage.
4
■
Low voltage outside of the specified
range is supplied to the main circuit
(R/S/T).
■
Check the main circuit voltage.
Confirm that there is no external
power supply to R/S/T when the main
circuit is OFF.
5
■
Defect in internal circuit of power unit
or amplifier unit.
■
Replace the power unit or amplifier
unit.
Status at the time of alarm
Cause
1
2
Issued when control power is turned ON.
✔
Issued when main circuit power supply is
turned ON
✔
✔
Issued during operation.
✔
✔
Cause
Investigation and corrective actions
1
■
One of 3 phases (R/S/T) is not
connected.
■
Check the wiring conditions and
correct it if improper.
2
■
Defect in internal circuit of s power
unit or amplifier unit.
■
Replace the power unit or amplifier
unit.
Summary of Contents for SANMOTION 3E S
Page 1: ...M0011696D Instruction Manual TYPE S For Rotary Motor Linear Motor Interface ...
Page 2: ......
Page 182: ...No Text on This Page ...
Page 200: ...No Text on This Page ...
Page 270: ...No Text on This Page ...
Page 336: ...No Text on This Page ...
Page 384: ...No Text on This Page ...
Page 408: ...No Text on This Page ...
Page 420: ...12 Appendix 12 10 12 4 Servo motor data sheet Refer another document M0011792 ...
Page 422: ...12 Appendix 12 12 12 5 3 RS3 03A HL 12 5 4 RS3A05A HL ...
Page 423: ...12 5 Servo amplifier dimensions 12 13 12 Appendix 12 5 5 RS3A07A HL 12 5 6 RS3A10A HA ...
Page 424: ...12 Appendix 12 14 12 5 7 RS3A15A HA 12 5 8 RS3A30A HL ...
Page 428: ...12 Appendix 12 18 12 5 13 RS3C02A HA 12 5 14 RS3C05A HA ...
Page 429: ...12 5 Servo amplifier dimensions 12 19 12 Appendix 12 5 15 RS3C10A HA 12 5 16 RS3C15A HL ...
Page 430: ...12 Appendix 12 20 12 5 17 RS3C30A HM ...
Page 484: ...12 Appendix 12 74 REGIST 1000W Wiring diagram ...
Page 486: ...No Text on This Page ...
Page 487: ...Release Revision A Sep 2017 Revision B Sep 2018 Revision C Dec 2018 Revision D Apr 2019 ...