11.3.9 Confirmation method of regeneration power PM in actual
operation
Regeneration power PM can be easily confirmed in the digital operator or by R ADVANCED
MODEL setup software.
■
Digital operator: Monitor mode ID40 "Regenerative Resistor Operation Percentage monitor"
■
Setup software: Monitor display ID40 "Regenerative Resistor Operation Percentage monitor"
* The monitor value of the regenerative resistor operation percentage shows the operating rate of
regeneration circuit.
* The display range is 0.00% - 99.9%.
■
The actual regeneration effective power PM can be calculated from this monitor value by
following equation.
Input Supply Voltage: In case of 200 VAC specification
Input Supply Voltage: In case of 100 VAC specification
Input Supply Voltage: In case of 400 VAC specification
■
Calculation Example
Input Supply Voltage: [200 VAC Specification]
Regeneration resistance value: 50
Ω
[Built-in Regenerative Resistor]
Monitor Value (RegP): 0.12%
* The regeneration power calculated from this monitor value continues to be the target until the
end of operations. Regeneration power varies with the voltage fluctuation of the input power
supply and changes across the ages of the servo amplifier and the loading device.
* Be sure to opt for selection of regeneration resistance based on the regeneration effective power
"PM" found from calculation of a pattern of operation and regeneration power.
* Install the external regeneration resistor on equipment, and measure the temperature of the
external regeneration resistor by the operating condition that the regeneration effective power
“PM” becomes the maximum. Then do sufficient mounting check of alarm not being generated. In
addition, it takes 1 to 2 hours until the temperature of the external regeneration resistor is
saturated.
400(V) × 400(V)
Regeneration
resistance(
Ω
)
×
100(%)
Regenerative Resistor
Operation Percentage (%)
Regeneration effective power [PM](W) =
200(V) × 200(V)
Regeneration
resistance(
Ω
)
×
100(%)
Regenerative Resistor
Operation Percentage (%)
Regeneration effective power [PM](W)
=
400(V) × 400(V)
Regeneration
resistance(
Ω
)
×
100(%)
0.12(%)
Regeneration effective power [PM](W)
=
= 3.84 (W)
800(V) × 800(V)
Regeneration
resistance(
Ω
)
×
100(%)
Regenerative Resistor
Operation Percentage (%)
Regeneration effective power [PM](W)
=
Summary of Contents for SANMOTION 3E S
Page 1: ...M0011696D Instruction Manual TYPE S For Rotary Motor Linear Motor Interface ...
Page 2: ......
Page 182: ...No Text on This Page ...
Page 200: ...No Text on This Page ...
Page 270: ...No Text on This Page ...
Page 336: ...No Text on This Page ...
Page 384: ...No Text on This Page ...
Page 408: ...No Text on This Page ...
Page 420: ...12 Appendix 12 10 12 4 Servo motor data sheet Refer another document M0011792 ...
Page 422: ...12 Appendix 12 12 12 5 3 RS3 03A HL 12 5 4 RS3A05A HL ...
Page 423: ...12 5 Servo amplifier dimensions 12 13 12 Appendix 12 5 5 RS3A07A HL 12 5 6 RS3A10A HA ...
Page 424: ...12 Appendix 12 14 12 5 7 RS3A15A HA 12 5 8 RS3A30A HL ...
Page 428: ...12 Appendix 12 18 12 5 13 RS3C02A HA 12 5 14 RS3C05A HA ...
Page 429: ...12 5 Servo amplifier dimensions 12 19 12 Appendix 12 5 15 RS3C10A HA 12 5 16 RS3C15A HL ...
Page 430: ...12 Appendix 12 20 12 5 17 RS3C30A HM ...
Page 484: ...12 Appendix 12 74 REGIST 1000W Wiring diagram ...
Page 486: ...No Text on This Page ...
Page 487: ...Release Revision A Sep 2017 Revision B Sep 2018 Revision C Dec 2018 Revision D Apr 2019 ...