- 92 -
7-2
Function Code List - Display Function / PID Function
Code No.
Function Name
Data Content
Setting
Resolution
Factory
Presets
User
Setting
Value
2303
2304
2305
LCD’s 1st display parameter setting
LCD’s 2nd display parameter
setting
LCD’s 3rd display parameter setting
0: No display
1: Frequency (Hz)
2: Output current (A)
3: Speed [rpm]
4: Load factor [%]
5: Output voltage [V]
6: DC voltage [V]
7: Active power [kW]
8: Apparent power [kVA]
9: Radiator temperature [
℃
]
10: Command speed [rpm]
11: PID1 feedback value [Hz]
12: PID2 feedback value [Hz]
13: VIF1 analog input value
14: VIF2 analog input value
15: VIF3 analog input value
16: Output torque [%]
17: Partial excitation current [A]
18: Partial torque current [A]
19: Detecting position [mm]
32: Command frequency (Hz)
33: Command torque [%]
38:Speed [rpm](subPG)(option)
42:Target frequency[Hz]
43:Output frequency[Hz]
1
1
2
4
2306
LCD backlight off time
0: Off
1
-
600 minutes: the time until it goes off
999: Normally on
1 minute
10
PID function
3001
PID1 command value input
switching
1: Frequency
2: External analog VIF1 voltage (0
-
5 V)
3: External analog VIF1 voltage
(0
-
10 V or potentiometer)
4: External analog VIF2 voltage (0
-
5 V)
5: External analog VIF2 voltage
(0
-
10V or potentiometer)
6: External analog VIF3 voltage (0
-
5 V)
7: External analog VIF3 voltage
(0
-
10V or potentiometer)
8: External analog VIF1 current (4
-
20mA)
9: External analog VIF2 current (4
-
20mA)
10: External analog VIF3 current (4
-
20mA)
11: Function code setting (F3017)
98:
Pulse train input subPG(option)
99: Pulse train input
1
1
3002
PID1 feedback input switching
0: No input
1: External analog VIF1 voltage (0
-
5 V)
2: External analog VIF1 voltage
(0
-
10 V or potentiometer)
3: External analog VIF2 voltage (0
-
5 V)
4: External analog VIF2 voltage
(0
-
10V or potentiometer)
5: External analog VIF3 voltage (0
-
5 V)
6: External analog VIF3 voltage
(0
-
10V or potentiometer)
7: External analog VIF1 current (4
-
20mA)
8: External analog VIF2 current (4
-
20mA)
9: External analog VIF3 current (4
-
20mA)
10: Communication mode
98: subPG
feedback PID (option)
99: PG feedback PID
1
0
3003
PID1 control proportional gain
0-100
0.01
0.1
3004
PID1 control integral time
0.01 -100 sec.
0.01s
0.1
3005
PID1 control differential time
0 -100 sec.
0.01s
0
3006
PID1 control integral separation
judgment value
5
-
100% (upper frequency limit reference)
0.1%
100
3007
PID1 feedback signal input filter
time constant
1-500
(
set value 1=10ms
)
.
1
10
3008
Indirect PID1 input reference
5
-
100% (target value reference)
0.1%
20
3009
PID1 deviation limit value
0: No limit
1
-
100% (upper frequency limit reference)
0.1%
100
3010
PID1 output limit value
0: No limit
1
-
100% (upper frequency limit reference)
0.1%
100
3011
PID1 operation polarity switching
1: Command value
-
feedback value
2: Feedback value
-
command value
1
1
3012
PID1 gain polarity switching
1: The positive or negative deviation indicates
the same gain
2: The positive or negative deviation indicates
different gains
1
1
3013
PID1 command value gain
0-50
0.01
1