- 36 -
4-5 Composition of Control Circuit Terminals
4-5-3
Multifunctional Input / Output
The so-called multifunctional input / output means freely assigning various functions to multifunctional input /
output terminals through the data selection of function codes.
The multifunctional input / output is divided into the input terminal of contact input and output terminal of open
collector.
(1) Multifunctional input terminals
Digital multifunctional input terminals DI1 - DI8 can be set to any one of the functions by using the
function codes F1414 - F1421 corresponding to various functions.
In addition, a multiplexed terminal may have several functions.
When the function code is set to F1414=13, for example, jog operation can be enabled simply by turning
the DI1 terminal on.
Table 4-4 Multifunctional input codes
Function code No.
Input terminal
name
Data range
Initial value (symbol)
F1414
DI1
0-255
1 (FR
)
F1415
DI2
2 (RR)
F1416
DI3
3 (2DF)
F1417
DI4
4 (3DF)
F1418
DI5
5 (MBS)
F1419
DI6
6 (ES)
F1420
DI7
7 (RST)
F1421
DI8
8 (AD2)
See description of selection functions of the input terminals DI1 - DI8 for details.
(2) Multifunctional output terminals
Digital multifunctional output terminals DO1-DO3 can be set as the open collector outputs of any one of
the functions by using the function codes F1509 - F1511 corresponding to various functions.
Table 4-5 Multifunctional output codes
Function code
No.
Input terminal
name
Data range
Initial value (function)
F1509
DO1
0-99
1 (In operation 1)
F1510
DO2
5 (Frequency matching)
F1511
DO3
8 (
Overload alarm level
setting
)
See description of selection functions of D01 - D03 for details.