- 122 -
11-3 Communication Function Specification
11-3 Communication function specification
Electrical characteristics
RS485 communication
Communication protocol
SANKEN protocol
Modbus-RTU
communication protocol
Communication type
4-wire / 2-wire bus type
(
RS485 standard
)
Transmission distance
Total 500m, terminal resistor is required
Number of units
connected
Max. 32
Max. 247
*
Note
Connection cable
Shielded twisted-pair cable recommended
Communication type
Full-duplex / Half-duplex
Communication speed
[bps]
57600/38400/19200/9600/4800/2400/1200 selectable
Synchronization
Asynchronous start/stop
Data format
ASCII code or BINARY
BINARY
Data length
8bit
Stop bit length
1bit or 2bit selectable
Parity check
Yes (odd, even), No, Selectable
Error check
SUM check
CRC code check
Message
end code
ASCII
CR+LF/CR selectable
No
BINARY
No
*
Note: A relay is required when exceeding 32
11-4 Storage Environment
Storage environments of
SVC06 series are as follows:
Table 11-1 Storage environment
Item
Description
Remark
Storage temperature
-20-65
℃
Short term during transportation
Relative humidity
95%RH or lower
Gas medium
No corrosive, gases, oil mist, dripping, dust or direct sunlight
Atmospheric pressure
86-106kPa
(1) Temporary storage
①
Never place it directly on the ground.
②
If equipment is stored in an environment which is worse than above mentioned, pack and seal the
equipment with polyvinyl resin plastic film, add an internal desiccant to prevent humidity.
(2) Long-term storage
①
When storage time exceeds 3 months, in order to prevent the deterioration of the electrolytic capacitors
caused by temperature, please adjust the ambient temperature to -10-+30
℃
.
②
Use desiccant, and keep the relative humidity in the package lower than 70%.
Summary of Contents for Samco SVC06
Page 1: ...High Performance Vector Control Inverter Instruction Manual Basic SANKEN ELECTRIC CO LTD...
Page 2: ......
Page 133: ...Memorandum...
Page 134: ...Memorandum...
Page 135: ......