- 109 -
-
109
-
C
h
ap
ter
10
10. Maintenance & Inspection
Never touch the internal parts.
Failure to obey may result in electrical shock, personal injury and other dangers.
Careful checking and maintenance are essential to ensure that the general-purpose inverter
SVC06 series can operate
correctly with a long service life.
10-1 Precautions on Checking and Maintenance
Capacitors retain a high voltage charge for a while after the power is turned off. Before carrying out
inspection, please firstly make sure that the CHARGE lamp is off, then make sure that the voltage across
terminals P and X is lower than DC30V using a circuit tester.
10-2 Inspection Items
The motor works as expected;
The cooling system is free from any problems (such as abnormal heating);
There is no abnormality at the location of installation; and
There is no abnormal vibration or noise.
Table 10-1 Inspection must be carried out following the periodic inspection list.
Table 10-1 Periodic inspection list
Inspection item
Inspection details
Method & Instrument
Criteria
G
en
er
a
l
Ambient
environment
Ambient temperature, relative
humidity
Confirm operating environment
Visual inspection, measuring
instrument
Thermometer & hygrometer
Satisfy standard
specifications
Power supply
voltage
Power supply voltage of the
inverter is normal.
Measure interphase voltage
of R, S and T input
terminals.
Use tester and multimeter
Satisfy standard
specifications of input
Appearance
Structural parts
No abnormal vibration or noise
No loosening of bolts
No deformation or breakage
No adhesion of dust or dirt
Tighten bolts
Visual inspection
No abnormal
Ma
in
Cir
cu
it
General
Megger check
No loosening of bolts
No adhesion of dust or dirt
Tighten bolts
Visual inspection
No abnormal
Connection
conductors
and wires
No deformation or dirt
No discoloration because of
overheating
Visual inspection
No abnormal
Main module
Check resistance between
terminals
Disconnect the main wiring
of the inverter and measure
each terminal with tester (x1
range)
Use analog tester
Refer to Table 10-2 Main
circuit power module
checklist
Summary of Contents for Samco SVC06