- 110 -
10-2 Inspection Items
Inspection item
Inspection details
Method & Instrument
Criteria
Ma
in
Cir
cu
it
Terminal board
No burning or breakage
Visual inspection
No abnormal
Main electrolytic
capacitor
No liquid leakage
No loosening of safety valve
Visual inspection
No
leakage,
deformation or crack
No action of the safety
valve
Relay
electromagnetic
contactor
No chatter during operation
No rough surface on the contact
No abnormal noise when the
switch is ON
Visual and hearing
inspection
No abnormal
Resistor
No disconnection
No odor or crack because of
overheating
Odor and visual inspection
Remove one-end and
check with tester
Use tester or multimeter
No abnormal
Within
±10%
of
indicated
resistance
value
Transformer
No abnormal beat sound or odor
Odor, visual and hearing
inspection
No abnormal
Co
n
tr
o
l
cir
cu
it
d
is
p
la
y
Connector
No loosening of connectors
No crack, breakage or
deformation
Visual inspection
No abnormal
Capacitor
No leakage, breakage or
deformation
Visual inspection
No abnormal
Board
No discoloration or dirt
Visual inspection
No abnormal
Display
No break in the LED lamp on
operation panel
No abnormality in key operation
Favorable display of characters
on LCD panel
Visual inspection
Make sure the lamp
lights up.
Make sure operations.
Co
o
li
n
g
sy
ste
m
Fan
No abnormal vibration or noise
No OH alarm
No loosening of bolts, wiring or
connectors
Visual and hearing
inspection
Tighten bolts, wiring and
connectors.
No abnormal
Ventilation flue
No blockage in cooling fan inlet
and outlet or contamination
adhesion of foreign objects.
Visual inspection
Tactile inspection
No abnormal
Fin
No abnormal heating
Tactile inspection or check
the temperature
Use thermometer
No abnormal
Mo
to
r
General
No abnormal vibration or noise
Visual and hearing
inspection
No abnormal
Insulation
resistance
Megger check
Disconnect the inverter
output wiring U, V and W,
then make an inspection
Use megger tester
Higher than 5MΩ