- 87 -
C
h
ap
ter
7
-
87
-
7-2
Function Code List
– Input/Output-Related Functions
Code No.
Function Name
Data Content
Setting
Resolution
Factory
Presets
User
Setting
Value
1508
Frequency matching range
0-10Hz
0.01Hz
0
1509
1510
1511
Selection of output terminal DO1
Selection of output terminal DO2
Selection of output terminal DO3
0: Unused
1: In operation 1
2: Undervoltage,
3:
End of simple scheduled operation
4: In operation 2,
5: Frequency matching (1st speed frequency)
6: Frequency matching (1st to 16th speed frequencies)
7: Frequency approach
8: Overload alarm level setting signal (the value of F1704)
9: Electric thermistor pre-alarm signal
(80% of electric thermistor)
10: Radiator overheat pre-alarm signal
,
13: Excitation and DC braking signals
14: Lower frequency limit matching signal
,
15: Upper frequency limit matching signal
,
16: Servo on ready signal,
17: Zero servo completion signal,
18: FR signal,
19: RR signal,
20: 2DF signal, 21: 3DF signal,
22: 5DF signal, 23: 9DF signal,
24: AD2 signal,
25: AD3 signal,
26: JOG signal,
27: MBS signal,
28: ES signal, 29: RST signal,
31: Positioning completion signal ,
32: Discharge resistor on signal,
34: Frequency counter (output frequency),
35: Frequency counter (command frequency),
36: Overload alarm level setting signal
(Including when in acceleration/deceleration ),
42: Torque matching signal
,
43: Low speed detection signal
47: Motor speed counter
48: Forward run detection signal
49: Reverse run detection signal
1
1
5
8
1512
Counter output multiple
1-100
1
1
1513
Relay 1 contact output selection
0: Alarm contact
1: In operation 1,
2: Undervoltage,
3: End of simple scheduled operation
4: In operation 2,
5: Frequency matching (1st speed frequency)
6: Frequency matching (1st to 16th speed frequencies)
7: Frequency approach
8: Overload alarm level setting signal (the value of F1704)
9: Electric thermistor pre-alarm signal
(80% of electric thermistor)
10: Radiator overheat pre-alarm signal
,
13: Excitation and DC braking signals
14: Lower frequency limit matching signal
,
15: Upper frequency limit matching signal
,
16: Servo on ready signal
17: Zero servo completion signal,
18: FR signal, 19: RR signal,
20: 2DF signal, 21: 3DF signal,
22: 5DF signal, 23: 9DF signal,
24: AD2 signal, 25: AD3 signal,
26: JOG signal, 27: MBS signal,
28: ES signal, 29: RST signal,
31: Positioning completion signal,
32: Discharge resistor on signal,
36: Overload alarm level setting signal
(Including when in acceleration/deceleration ),
42: Torque matching signal
,
43: Low speed detection signal
48: Forward run detection signal
49: Reverse run detection signal
1
0
1515
Current output multiple
0-20
0.01
1
1516
Torque matching level
0-±200%
0.1 %
100
1517
Torque matching range
0-50%
0.1 %
25
1518
Low speed matching level
0-2,000rpm
1rpm
100
1519
Low speed matching range
0-100rpm
1rpm
10
Summary of Contents for Samco SVC06
Page 1: ...High Performance Vector Control Inverter Instruction Manual Basic SANKEN ELECTRIC CO LTD...
Page 2: ......
Page 133: ...Memorandum...
Page 134: ...Memorandum...
Page 135: ......