- 52 -
5-3
Status Display Mode
(2)
Frequency setting B
Frequency setting B is a method for changing frequency by dialing the quick knob each time.
This is an effective method for fine-tuning of the set frequency during observation of the load conditions.
In status monitor display, this method can be used either in running or stopped state of the equipment.
This method can not be used during alarm display.
Operation example: changing the frequency from 5 Hz to 50 Hz
Operation
Display
Description
or
Display of status monitor (frequency display)
(long press)
Press the quick knob, and the current set frequency will
be displayed
…
Turn the quick knob, and the value displayed will
increase or decrease. The frequency changed by turning
the quick knob will be stored immediately as a new
frequency value. If this is done during running
operation, then the output frequency will start to change
to the newly set value.
…
Quickly turn the knob, and the displayed digit number
of increase or decrease will be changed.
The frequency desired is reached.
or
(press)
or
Press the
key or quick knob, then the display
screen will return to status monitor display. Also, the
display screen will return to the status monitor display
if the quick knob is not operated in seconds (* 1).
(
*2
)
:Lit : Brightness periodically changes : Flashing
*1 Under no-operation condition, the time before the display screen returns to status display can be changed through function
codes, see the contents of function code F1607.
*2 Although the display can be switched back to the status monitor display through (Back) key or key, the set
frequency is still active.