SAMSUNG
Programming
DCS-816
February, 1999
MMC 501 (Page 6 of 7)
LCR INTER DIGIT:
This timer controls the grace period between dialling valid
digits before dropping the call and returning the user to
error tone.
MCL DELAY TIME:
This timer controls the time when the system should start
transmitting Authorisation code after sending MCL
Access code.
OFF HOK RING INT:
This timer controls the duration of time between ring
bursts to a user who has a camped–on call.
receive CAMP–ON when busy
ß
off hook ring
à
off hook ring interval
ß
off hook ring
à
OFF HOOK SELECT:
This timer controls the grace period before placing a
internal/external call as programmed in MMC 306.
lift handset
ß
off hook select time
à
starts placing a call as specified in
MMC 307
OHVA ANS TIME:
This timer controls the time duration of an OHVA call
before automatic rejection. When a user receives OHVA
with voice interrupt this situation will last until this timer
expires. If LCD phones receive OHVA, REJECT will
appear at righthand side of bottom line while this timer is
activated.
OVERLAP INT DGT:
This timer controls the grace period between receiving
address information in overlap receiving mode via
BRI/PRI line. After expiration of this timer the system
operator will be alerted.
PAGE TIME OUT:
This timer controls the duration of a page announcem–
ent.
PAGE TONE TIME:
This timer controls the duration of tone burst heard over
the page prior to the page announcement.
PARK RECALL TIME:
This timer controls the duration of time a call is parked
before recalling to the call park originator.
PC–MMC LOCKOUT:
This timer monitors PCMMC activity, drops the link if no
action is created by PCMMC and returns the system to
secure program status.
POWER DOWN TIME:
This timer monitors the power down to the SLT line for
VM/AA.
RECALL DISCONN:
This is the time an attendant recall rings before being
disconnected. See
ATT Recall Time
.
RECALL WAIT TIME:
This is the time any recall (hold or transfer) continues to
recall at your station before it recalls to the operator.
1) If Originator is idle:
e
–
hold
ß
e
–
hold recall time
à
recall to
ß
att recall
à
recall to
ß
recall
à
disconnect
transfer transfer recall time originator time operator disc.time
Summary of Contents for DCS-816
Page 1: ...General Description for Europe DCS 816 ...
Page 2: ...Programming Manual DCS 816 ...
Page 239: ...Part No GA68 60754A ED 01 Printed in Korea ...
Page 240: ...Installation Manual for Europe DCS 816 ...
Page 263: ...SAMSUNG Installation DCS 816 February 1999 4 4 This page is intentionally left blank ...
Page 285: ...Part No GA68 60751A ED 01 Printed in Korea ...
Page 286: ...System Administration and Special Features Guide DCS 816 ...