SAMSUNG
Programming
DCS-816
February, 1999
MMC 207 (Page 1 of 1)
MMC: 207
ASSIGN VM/AA PORT
DESCRIPTION:
Enables SLI ports to be designated as NORMAL or VMAA. VMAA ports receive
digits designated in MMC 726, VM/AA Options, and also receive a true
disconnect signal upon completion of a call. Only SLI cards, not keyset daughter-
boards, support disconnect signal. Do not make VMAA ports data; this will return
them to a single line port and stop voice mail integration. VMAA ports have the
equivalent of data protect written in the program and are protected against tones.
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Move cursor left and right
SPK
Used to store data and advance to next MMC
HOLD
Used to clear previous entry
ANS/RLS
Used to select ALL
ACTION
DISPLAY
1.
Press TRSF 207
Display shows
[213] VMAA PORT
NORMAL PORT
2.
Dial station number (e.g., 215)
OR
Press UP or DOWN to select station
and press RIGHT soft key to move cursor
[215] VMAA PORT
NORMAL PORT
3.
Dial 1 or 0 to select port type (1=VMAA,
0=NORMAL)
OR
Press UP or DOWN to select option and
press RIGHT soft key
[215] VMAA PORT
VMAA PORT
4.
Press TRSF to store and exit
OR
Press SPK to store and advance to next
MMC
DEFAULT DATA: Normal port
RELATED ITEMS: MMC 726 VM/AA Options
MMC 601 Assign Station Group
Summary of Contents for DCS-816
Page 1: ...General Description for Europe DCS 816 ...
Page 2: ...Programming Manual DCS 816 ...
Page 239: ...Part No GA68 60754A ED 01 Printed in Korea ...
Page 240: ...Installation Manual for Europe DCS 816 ...
Page 263: ...SAMSUNG Installation DCS 816 February 1999 4 4 This page is intentionally left blank ...
Page 285: ...Part No GA68 60751A ED 01 Printed in Korea ...
Page 286: ...System Administration and Special Features Guide DCS 816 ...