5.3 Off Premise Extension (OPX) (Figure 5-3)
The Basic KSU is equipped with four (4) SLI interfaces and only the first two (2) SLI interfaces are
specially designed for Long Line or Off Premise Extension (OPX) connections. The interfaces
have the same over-voltage and over-current protection circuits as an analogue trunk interface.
All connections for OPX lines can be done through the RJ-45 connector on the base board. See
Figure 2-3 and refer to the section 2.5 (MDF Cabling).
Use one pair twisted wires and connect each OPX line to the SLI port of your choice via the RJ-45
connector on the base board.
CONNECTING OPX LINES
FIGURE 5-3
RJ-45 CONNECTION
PIN COLOUR
CIRCUITS/ FUNCTIONS
1/ 8 W-BL/ BL-W
T/R, 1
st
SLI on base board
2/ 7 W-O/ O-W
T/R, 2
nd
SLI on base board
4 PAIR CABLE WITH MALE CONNECTOR TO THE BASE RJ-45 CONNECTOR
Long Line
Extension
²
NO POLARITY
²
A LOOP-DISCONNECT FACILITY PER LINE
²
CONNECT TO ONE OF THE 1
ST
OR THE 2
ND
SLI
CIRCUITS ON THE BASE BOARD VIA THE RJ-45
CONNECTOR.