7.10 Information on DCS-816 Serial Interface (Figure 7-8)
There is a variety of data terminal equipment and data communication equipment at sites and
sometimes it may be confusing how to connect the equipment to the SIO1 card. Generally, the
connections described in sections 7.5 to 7.7 are sufficient to work most equipment. However, the
following, more detailed information, should help if you encounter any problems.
The signal “DSR (6)” is pulled-up with a resistor in the serial interface which meets the
requirements of most data equipment. However, some printers cannot operate with the pull-up
resistor and may cause trouble. If so, DCD (1) may replace DSR (6).
For signalling protocol, all parameters can be adjusted with relevant programming (MMCs 725 and
804) and the default settings are as follows:
Serial Port 1: PCMMC
Serial Port 2 : SMDR
SIO Protocol
1 Start bit, 8 data bits, 1 Stop bit, No parity
9600 Baud rate, No DSR check, 3 times retry
INFORMATION ON SERIAL INTERFACE
FIGURE 7-8
SIO1 BOARD (DTE DB9)
DCD (1)
RXD (2)
TXD (3)
DTR (4)
Input, Carrier Detect, Optional, Replacing DSR sometimes
Input, Received Data, Essential
Output, Transmitted Data, Essential
Output, DTE Ready, Essential
GND (5)
Signal Ground, Reference, Essential
DSR (6)
Input, DCE Ready, Essential, Replaced with DCD sometimes
RTS (7)
Output, Request to Send, Optional
CTS (8)
RI (9)
Input, Clear to Send, Not Connected
Ring Indicator, Not Connected
Summary of Contents for DCS-816
Page 1: ...General Description for Europe DCS 816 ...
Page 2: ...Programming Manual DCS 816 ...
Page 239: ...Part No GA68 60754A ED 01 Printed in Korea ...
Page 240: ...Installation Manual for Europe DCS 816 ...
Page 263: ...SAMSUNG Installation DCS 816 February 1999 4 4 This page is intentionally left blank ...
Page 285: ...Part No GA68 60751A ED 01 Printed in Korea ...
Page 286: ...System Administration and Special Features Guide DCS 816 ...