Figure 5.6
Functional architecture for data collection, history and thresholding treatment
5.2.2
Performance Values
Threshold Seconds (TS)
The TS is defined as one second period during which the detected value is outside of predefined
thresholds. The current value of the counter associated with TS should be readable by the managing
system on request. In case a threshold associated to TS counter is changed, the current value of the
counter should be reset to zero.
Tide Mark (TM)
The TM is a mechanism that records the maximum and the minimum value reached during
measurement period. The tide mark values are automatically reset to the current value assumed at
the beginning of each measurement period. The TM is therefore composed of two values: the
minimum and the maximum value. Comparison between the current value and the minimum and
maximum values is performed on a second basis.
5.2.3
Performance Management in Web GUI
The main performance management tool in the CFIP PhoeniX is Web interface, allowing user to
review performance measurements in a very convenient and visualized way.
Going to ‘Performance
Performance log’ in navigation panel on the left side of the Web GUI
window will lead you to the log parameters’ selection screen, where you will be able to choose
between 10 different parameters to display in summarizing performance log or pick ‘ALL’ to display all
10 parameters in conjoint log which is shown in
Figure 5.7.
CFIP PhoeniX Series TDM/IP Split Mount System Technical Description and Configuration Guide
•
Rev. 1.13
•
© SAF Tehnika JSC 2015