Ethernet
switch
Modem
IDU4
192.168.205.13
ODU3
ODU4
ODU1
ODU2
IDU1
192.168.205.10
Ethernet
switch
Modem
Modem
IDU3
192.168.205.12
IDU2
192.168.205.11
Ethernet
switch
Modem
Protection mode: Working
Protection mode: Protection
Protection mode: Working
Protection mode: Protection
P1
P4
P3
P2
Protection cable
Protection cable
Eth.
Port disabled
Protection switch
1+1
F=F1
F=F1
F=F2
F=F2
Working link
Protection link
Eth.
Ethernet
switch
Port disabled
Protection switch
1+1
Figure 4.10
CFIP PhoeniX FD mode
1.
Connect each IDU to appropriate ODU. Note that High ODUs should be at one site and Low
ODUs at remote site.
2.
IDU pairs must be interconnected as shown in
Figure 4.9
.
3.
Before power is supplied to equipment:
-
both IDUs on each side of the link should be grounded;
-
switches of IDUs must be set to correct state. For working link protection mode switch
on CFIP PhoeniX IDU front panel should be set to “1+0” position and for protection
link protection switch should be to “1+1” position as shown in
Figure 4.10
.
4.
Choose different frequencies for ‘working’ and ‘protection’ links as shown in
Figure 4.10
: F1
and F2.
5.
Supply the IDUs with power and proceed with configuration.
Configuration of 1+1 Frequency Diversity (FD) mode
It is possible to perform configuration in Web GUI or through CLI (serial or telnet connection).
For detailed description of commands necessary for 1+1 configuration refer to Chapter 4.3.5.
For 1+1 FD mode it is necessary to:
•
Assign different IP addresses for each IDU. Note that IP addresses should be within the
same subnet;
•
Set different frequency pairs for working and protection links as shown in
Figure 4.10
: F1
and F2;
•
Set appropriate state (working/protection) for each IDU;
•
Disable automatic remote IP address identification (set by default) in “Tools
Command
line” with command “modem ipremote off” and set appropriate remote site IP address for
each IDU in “Configuration
IP configuration”: “Remote IP address” for local working IDU
is “IP address” of remote working IDU and “Remote IP address” for local protection IDU is
”IP address” of remote protection IDU.
Example of configuration for FD mode:
CFIP PhoeniX Series TDM/IP Split Mount System Technical Description and Configuration Guide
•
Rev. 1.13
•
© SAF Tehnika JSC 2015
48