Pin type
Pin number
Pin type
Pin number
Alarm input 1
1
Ground
12
Alarm input 2
2
Ground
13
Alarm input 3
3
Alarm output 4 NC
15
Alarm input 4
4
Alarm output 3 NC
16
Alarm output 4 NO
6
Alarm output 2 NC
17
Alarm output 3 NO
7
Alarm output 1 NC
18
Alarm output 2 NO
8
Alarm output 4 COM
23
Alarm output 1 NO
9
Alarm output 3 COM
24
Ground
10
Alarm output 2 COM
25
Ground
11
Alarm output 1 COM
26
Electrical specifications of auxiliary alarm inputs
•
Nominal open output voltage: 5V;
•
Nominal closed contact current: 1 mA;
•
Maximum closed contact resistance: 800
Ω
;
•
Minimum open contact resistance: 10 k
Ω
.
Electrical specifications of auxiliary alarm outputs
•
Max. switching voltage: 68 VDC;
•
Max. switching current (steady state): 2 A;
•
Max. contact resistance: 75 m
Ω
.
10.4
RS232 (DB9 female connector)
Figure 10.4
RS232 DB9 port pinouts
10.5
1+1 protection port (RJ-45)
The pinouts of RJ45 socket are as follows:
Unassigned
Unassigned
Received from DTE
Transmitted from DCE
Transmitted Data
Received Data
DTE Ready
Signal Ground
DCE Ready
Request to Send
Clear to Send
Shield
1
2
3
4
5
6
7
8
9
CFIP PhoeniX Series TDM/IP Split Mount System Technical Description and Configuration Guide
•
Rev. 1.13
•
© SAF Tehnika JSC 2015
115