Figure 4.40
Ethernet aggregation configuration for Master
1.
Role
– choose
“Master”
;
2.
Mode
– choose “Aggregation” for link aggregation 2+0;
3.
Revertive mode
– in case of “enabled” setting link will automatically reconfigure back to 2+0
operation when unit/cable/link failure is resolved. In case of “disabled” setting link will
continue to operate in 1+0 mode; In order to activate 2+0 manually, it is necessary to press
“Change state: Active” button on any of two Slave units.
4.
In “Master aggregation/protection table” set the following:
a.
IP address of Master unit (you are configuring)
b.
IP address of Slave unit (directly connected to Master unit
a
)
c.
Link ID for Master link (same Link ID should be set on second Master unit)
d.
Link ID for Slave link (same Link ID should be set on second Slave unit)
e.
LAN port number which will be used as Traffic port (connection to external switch)
f.
LAN port number which will be used as Aggregation/Protection port (connection
with Slave unit)
5.
Add entry
– use to add additional Slave units (in case of 3+0 or 4+0 configurations);
6.
Pressing
„Execute configuration”
applies changes made to the corresponding section only for
the local side CFIP PhoeniX. If
„Rollback on”
is selected, configuration will be reverted in case
of erroneous configuration changes applied;
7.
Writes to configuration file all the changes made on the whole page (command line –
cfg
write
);
8.
System returned -
in case of error or incorrectly entered parameter value, or other problems
on the whole page – the info message is being shown here. Otherwise it says “Ok”.
Configuration for local slave unit:
CFIP PhoeniX Series TDM/IP Split Mount System Technical Description and Configuration Guide
•
Rev. 1.13
•
© SAF Tehnika JSC 2015
66