RCP-QE User Guide (v02)
Setting Up the RCP-QE • 4–29
For More Information on...
• resource management, refer to “
Setting Up Virtual Routing and Resource Management
To assign a de-assign button:
1.
Open the RCP-QE Panel Configuration editor (see “
Opening the RCP-QE Panel Configuration Editor
2.
On the simulated RCP-QE, select the button from which to de-assign a machine control port.
The
Button
configuration box opens.
3.
In the
Button
list, select
Function Key
.
4.
Use the
Value
list to select
Deassign
.
5.
Close the
Button
configuration box.
The simulated RCP-QE in DashBoard shows
DE-ASIGN
on the selected button.
6.
Send the current configuration file to the device (see “
Sending a Configuration File to a Device
Linking Remote Control Panels
If your routing switcher system is extensive, control of the entire system may not be possible through just one
remote control panel. If this is the case, additional remote control panels may be added, as described on“
” on page 3–1. You can choose to operate the remote control panels individually, or you can link the
remote control panels together so they operate as one larger remote control panel.
When multiple remote control panels are linked, the Address field must be the same for all linked remote control
panels, and the Panel Link Address field must be different for each remote control panel.
For More Information on...
• operating linked remote control panels, refer to the section “
Operating Linked Remote Control Panels
You may link RCP-ME, and RCP-QE, RCP-NKM, and RCP-NKQ remote control panels together. You cannot link
the RCP-NK1 with an RCP-ME, or RCP-QE, RCP-NKM, or RCP-NKQ. You may link up to 10 remote control
panels together.
RCP-QE panel linking requires a connection to either an NK-NET, an Ultrix router, or an Ultricore Central
Controller. The NK-IPS does not support panel linking.
The
Panel Address
and
Panel Link Address
must be different within each remote control panel. For example, if
you have three RCP-QE panels but only want to link two panels, you would assign the Panel Address and Panel
Link Addresses as outlined in
. In this example, the first and second panels are linked to form one logical
remote control panel.
To link remote control panels together:
1.
Launch the RCP-QE editor as outlined in the section “
Opening the RCP-QE Connection Editor
2.
In the
Address
field of the
Device Details
area, enter the common address (between 2 and 255) that you want
all the linked remote control panels to use.
Table 4.5 Example of Linked Panel Addresses
First RCP-QE
Second RCP-QE
Third RCP-QE
Setup
Linked
Unlinked
Address
100
100
120
Panel Link Address
1
2
0
Summary of Contents for NK Routing Systems RCP-QE
Page 1: ...RCP QE User Guide Version 02 ...
Page 10: ...1 2 Introduction RCP QE User Guide 02 ...
Page 14: ...2 4 RCP QE Overview RCP QE User Guide v02 ...
Page 20: ...3 6 Installation RCP QE User Guide v02 ...
Page 66: ...6 2 Troubleshooting RCP QE User Guide v02 ...
Page 68: ...7 2 RCP QE Hexadecimal to Router Level Conversion RCP QE User Guide v02 ...