RCP-QE User Guide (v02)
Setting Up the RCP-QE • 4–23
Assigning a Name to a Macro Using DashBoard
Macros can be assigned custom names in DashBoard using the
Macro Names
tab.
To assign a name to a macro using DashBoard:
1.
In
DashBoard
, select the
Macro Names
tab.
2.
In the
Name
column, perform the following:
a.
Click inside the
Name
table cell of the macro.
b.
Enter a name.
c.
Press
Enter
.
The macro name is added to the button.
Assigning a Protect Button
To prevent switching of critical crosspoints by others, assign a protect button for use on the RCP-QE. The protect
function ensures that the selected destination can only receive the selected source across the selected levels. Once
protected, the selected levels on a destination cannot be switched by other remote control panels (or by the same
remote control panel if
Block All Panels
is selected). The source is not protected and can be freely routed to other
destinations if required. You can protect any number of destinations. For more information see “
You can also use the protect button to lock the RCP-QE against all button presses (see “
To assign a protect button using DashBoard:
1.
Open the RCP-QE Panel Configuration editor (see “
Opening the RCP-QE Panel Configuration Editor
2.
On the simulated RCP-QE, click the button that you want to use for the level.
The
Button
configuration box opens.
3.
In the
Button
list, select
Function Key
.
4.
In the
Value
list, select
Protect
as the function to assign to this button.
5.
Close the
Button
configuration box.
The simulated RCP-QE in DashBoard shows the protect (
PROT
) on the button.
6.
Select the
Configuration
tab.
7.
In the
Configuration
section, select the mode of protection that you want to use for the protect button. Use the
as a guide:
8.
Send the current configuration file to the device (see “
Sending a Configuration File to a Device
Table 4.4 Protect Mode Descriptions
Protect Mode
Description
Block Other
Panels
The protected destination and level(s)
cannot
be switched to another source
by other remote control panels.
The protected destination and level(s)
can
be switched to another source on
the current remote control panel.
Block All Panels
The protected destination and level(s)
cannot
be switched to another source
by the current remote control panel or other remote control panels.
Summary of Contents for NK Routing Systems RCP-QE
Page 1: ...RCP QE User Guide Version 02 ...
Page 10: ...1 2 Introduction RCP QE User Guide 02 ...
Page 14: ...2 4 RCP QE Overview RCP QE User Guide v02 ...
Page 20: ...3 6 Installation RCP QE User Guide v02 ...
Page 66: ...6 2 Troubleshooting RCP QE User Guide v02 ...
Page 68: ...7 2 RCP QE Hexadecimal to Router Level Conversion RCP QE User Guide v02 ...