4–8 • Setting Up the RCP-QE
RCP-QE User Guide (v02)
Output/Input Assigns
Number of outputs/inputs (increments of 8)
– enter or select a number of outputs/inputs. The number must be
changed in increments of eight.
Update
– click this button to update the output/input assigns.
Copy to Input/Output Assigns
– click this button to transfer the number of outputs/inputs to the other assigns tab.
The labels are imported as well.
Import Global Labels
– click this button to import global labels for the outputs/inputs.
Output/Input Range
– use this list to select the range of outputs/inputs to view in the Output/Input Assigns. The
assigns tab will only display the I/O ranges in blocks of 120 outputs/inputs at a time, with each block selectable in
the range list.
Out/In
(read-only) – the output/input number.
Label
– click inside the table cell to edit or enter a name for the output/input. If you have configured global labels,
the labels can also be filled in by clicking the
Import Global Labels
button.
Display Options
Mode
– the type of button function.
Default Color
– click inside the table cell and use the list to select a color for the button when it is not selected or
active.
Invert Default
– select the check box to invert the text on the button when it is not selected or not active.
Selected Color
– click inside the table cell and use the list to select a color for the button when it is selected or
active.
Invert Selected
– select the check box to invert the text on the button when it is selected or active.
Use the simulated button examples on the right side of the table to view the currently selected button display
configuration.
Macro Names
#
(read-only) – the macro number.
Name
– click inside the table cell to enter a name for the macro.
Macro Events Tab
Macro
#
(read-only) – the macro number.
Num. Rows
– enter or select the number of event rows to add to the macro.
Update
– click this button to update the macro with the number of rows entered in the
Num. Rows
box.
Event
(read-only) – the macro event number. Triggering the macro will trigger events in this order.
Function
– use the list to select a function to perform with the macro:
•
Switch
– performs a standard crosspoint switch.
•
Macro
– performs a macro within the executed macro.
•
Protect
– creates a protect condition on the destination of the selected crosspoint.
Output
– click inside the table cell to enter or edit the destination output.
Input
– click inside the table cell to enter or edit the source input.
Level Mask (1...32)
– select the level mask(s) for the device affected by the macro.
Clear
– click to clear the level mask(s).
Summary of Contents for NK Routing Systems RCP-QE
Page 1: ...RCP QE User Guide Version 02 ...
Page 10: ...1 2 Introduction RCP QE User Guide 02 ...
Page 14: ...2 4 RCP QE Overview RCP QE User Guide v02 ...
Page 20: ...3 6 Installation RCP QE User Guide v02 ...
Page 66: ...6 2 Troubleshooting RCP QE User Guide v02 ...
Page 68: ...7 2 RCP QE Hexadecimal to Router Level Conversion RCP QE User Guide v02 ...