RCP-QE User Guide (v02)
Setting Up the RCP-QE • 4–11
Button Assignments
By default, the 17 buttons on the RCP-QE are assigned the following functions:
• buttons 1 to 6: destinations (outputs 1 to 6, respectively)
• buttons 7 to 13: sources (inputs 1 to 7, respectively)
• button 14: Level 1
• button 15: Macro 1
• button 16: Menu 2
• button 17: Menu 3
Assigning Physical Connections for Control by an RCP-QE
Source and destination equipment is physically connected to routing switchers. This connection information must
be displayed meaningfully on the RCP-QE. This information is set up on the
Input Assigns
and
Output Assigns
tabs.
Selecting the Number of Outputs/Inputs
Depending on the size of the routing switchers connected, you may choose to increase or reduce the number of
output and input labels to match the size of the routing switcher if virtual routing is not used. The number can be
changed in increments of 8.
If the RCP-QE is connected to an Ultrix router or Ultricore Central Controller, the number of inputs and outputs
are defined by the Ultrix/Ultricore set up. Changes to Ultrix or Ultricore will overwrite any manual changes
made on the remote control panel.
To change the number of possible inputs and outputs:
1.
Open the RCP-QE Panel Configuration editor (see “
Opening the RCP-QE Panel Configuration Editor
2.
Perform one of the following:
• To change the number of outputs, select the
Output Assigns
tab.
• To change the number of inputs, select the
Input Assigns
tab.
3.
Use the
Number of outputs
/
Number of inputs
box to enter or select the number of outputs/inputs to match
the requirements of your routing switcher system.
4.
Click
Update
.
5.
If you want to transfer this number of outputs/inputs to the other tab, click
Copy to Input Assigns
/
Copy to
Output Assigns
. The labels are also copied.
6.
Send the current configuration file to the device (see “
Sending a Configuration File to a Device
Assigning Output and Input Labels
To assign output and input labels:
1.
Open the RCP-QE Panel Configuration editor (see “
Opening the RCP-QE Panel Configuration Editor
2.
Perform one of the following:
• To change the label for an output, select the
Output Assigns
tab.
• To change the label for an input, select the
Input Assigns
tab.
Summary of Contents for NK Routing Systems RCP-QE
Page 1: ...RCP QE User Guide Version 02 ...
Page 10: ...1 2 Introduction RCP QE User Guide 02 ...
Page 14: ...2 4 RCP QE Overview RCP QE User Guide v02 ...
Page 20: ...3 6 Installation RCP QE User Guide v02 ...
Page 66: ...6 2 Troubleshooting RCP QE User Guide v02 ...
Page 68: ...7 2 RCP QE Hexadecimal to Router Level Conversion RCP QE User Guide v02 ...