4–12 • Setting Up the RCP-QE
RCP-QE User Guide (v02)
3.
Click to highlight the text in the
Label
column corresponding to the output/input to which the item of
destination/source equipment is connected.
4.
Enter the name of the item of destination/source equipment.
5.
Press
Enter
.
The name of the item of destination/source equipment appears on the corresponding button on the simulated
RCP-QE in DashBoard.
6.
Repeat step 1 to 5 until all of the outputs and inputs on the routing switchers have been assigned a label for the
connected destination and source equipment.
7.
If you want to transfer the labels for the outputs/inputs to the other assigns tab, click
Copy to Input
Assigns
/
Copy to Output Assigns
.
The number of outputs/inputs is also copied.
8.
Send the current configuration file to the device (see “
Sending a Configuration File to a Device
If there are various router levels using this output or input number, the label may be ambiguous if the destination
or source is different for those levels.
You may rearrange the layout of the labels on the buttons when you assign functions to the buttons (see
“
Assigning Functions to Buttons on the RCP-QE
Setting Up Breakaways
A breakaway selects a group of levels to be switched. The default breakaway for the RCP-QE is the first eight
router levels switching together (they are tied). If your routing switcher system does not use all of the predefined
router levels (see
), you should disable those levels that are not used in order to prevent a breakaway
warning. If you only want to switch certain router levels, set up a custom breakaway for these levels and then assign
this to a button on the RCP-QE (see “
Assigning Functions to Buttons on the RCP-QE
select a breakaway that includes a level for which there is no routing switcher assigned, a breakaway warning is
indicated by three bars (
|||
) in the bottom right corner of the button on the panel.
If the RCP-QE is connected to an Ultrix router or Ultricore Central Controller, the level numbers for setting
breakaway pattern correspond to the
ID
column within the Ultricore
Levels
tab.
To set up the breakaways:
1.
Open the RCP-QE Panel Configuration editor (see “
Opening the RCP-QE Panel Configuration Editor
2.
Select the
Configuration
tab.
3.
In the
Tied
level mask of the
Breakaways
section, de-select the router levels that are not used in your routing
switcher system by clicking on the numbered squares. A selected router level is indicated by a blue square.
For example, if router levels 2 and 3 are the only levels used, you should de-select levels 1, 4, 5, 6, 7, and 8 in
the
Level Mask
column corresponding to
Tied
.
The
Tied
breakaway is the default. It is breakaway
# 1
in the table.
4.
Double-click inside the
Name
column in the breakaway (
# 2
) below
Tied
.
5.
Enter a name for the router level that corresponds to the first custom breakaway that you want to define.
For example, enter
SDI
.
6.
Select the corresponding router level(s) in the
Level Mask
column (see
), and de-select any router
levels that are not used.
7.
Define the next custom breakaway in the
Name
column below the breakaways that you have defined
previously. Repeat steps 3 to 7 until you have defined all the custom breakaways that you want to use.
Summary of Contents for NK Routing Systems RCP-QE
Page 1: ...RCP QE User Guide Version 02 ...
Page 10: ...1 2 Introduction RCP QE User Guide 02 ...
Page 14: ...2 4 RCP QE Overview RCP QE User Guide v02 ...
Page 20: ...3 6 Installation RCP QE User Guide v02 ...
Page 66: ...6 2 Troubleshooting RCP QE User Guide v02 ...
Page 68: ...7 2 RCP QE Hexadecimal to Router Level Conversion RCP QE User Guide v02 ...