4–28 • Setting Up the RCP-QE
RCP-QE User Guide (v02)
3.
In the
Configuration
section, select the
Panel Locked
check box.
4.
Send the current configuration file to the device (see “
Sending a Configuration File to a Device
The RCP-QE is locked.
If a panel lock button is assigned, it can be pressed to unlock the RCP-QE.
If a protect button is assigned, it can be held to unlock the RCP-QE.
If neither of these buttons are assigned, the RCP-QE can only be unlocked by clearing the
Panel Locked
check
box in DashBoard and then sending the configuration file to the device.
Setting Up Machine Control
If your routing switcher system uses a machine control routing switcher to provide reciprocal switching of RS-422
signals, your RCP-QE must be set up to handle these switches. Machine control must be enabled in the RCP-QE
and the router level used for machine control must match that set in the machine control routing switcher.
To set up machine control:
1.
Open the RCP-QE Panel Configuration editor (see “
Opening the RCP-QE Panel Configuration Editor
2.
Select the
Configuration
tab.
3.
In the
Configuration
section, select the
Machine Control Enabled
check box.
4.
Use the
Machine Control Level
box to enter or select the machine control level to match the level that the
machine control routing switcher has been assigned.
5.
Send the current configuration file to the device (see “
Sending a Configuration File to a Device
Assigning a Machine Control Button
If your master device controls multiple slave devices, you need a machine control button to temporarily disable
reciprocal switching until the last slave device is routed.
To assign a machine control button:
1.
Open the RCP-QE Panel Configuration editor (see “
Opening the RCP-QE Panel Configuration Editor
2.
On the simulated RCP-QE, select the button that you want to use for machine control.
The
Button
configuration box opens.
3.
In the
Button
list, select
Function Key
.
4.
Use the
Value
list to select
MC Key
.
5.
Close the
Button
configuration box.
The simulated RCP-QE in DashBoard shows
MC KEY
on the selected button.
6.
Send the current configuration file to the device (see “
Sending a Configuration File to a Device
Assigning a De-assign Button
De-assign will disconnect a reciprocal machine control path through a machine control router, parking sources to
their respective destinations. Similarly, if using resource management, de-assigning will park the resource inputs
and outputs and de-allocate the resource to be used in other routes.
Summary of Contents for NK Routing Systems RCP-QE
Page 1: ...RCP QE User Guide Version 02 ...
Page 10: ...1 2 Introduction RCP QE User Guide 02 ...
Page 14: ...2 4 RCP QE Overview RCP QE User Guide v02 ...
Page 20: ...3 6 Installation RCP QE User Guide v02 ...
Page 66: ...6 2 Troubleshooting RCP QE User Guide v02 ...
Page 68: ...7 2 RCP QE Hexadecimal to Router Level Conversion RCP QE User Guide v02 ...