Or:
System Status
Firmware version: topex-3.0.6-FA-S
Ethernet link up
PPP link online, IP=10.96.148.115
PPPOE link offline
System uptime: 19:27:57 up 20 min, load average: 0.22, 0.14, 0.07
DHCP Leases:
1363095959 00:06:4f:02:15:82 192.168.1.13 VO000073 01:00:06:4f:02:15:82
1363095959 6c:f0:49:76:24:4b 192.168.1.12 * 01:6c:f0:49:76:24:4b
two categories of information are displayed in System Status:
-
Equipment info
, permanent data, which is important for this chapter – the exact firmware
version;
-
System info
, with temporary (current) data, such as state of different links (ETH, PPP, PPPoE)
uptime, load, DHCP leases, etc;
The
permanent
identification info shown refers to the Firmware version: topex-3.0.5-FA-S-g, topex-3.0.6-
FA-S, orange-3.0.1-FA-O and so on.
Format for the Name of the firmware image file:
[brand]-[version]-[type]-[release]-[package].trx
brand - indicates the brand used for the respective firmware. It may be Topex, Omniacom, Vodafone,
Orange , etc.
version – the firmware version, three numbers divided by decimal points, such as 1.2.1 or 2.0.7 or 3.0.6
type - mobile network used for the product ( HSPA, CDMA, UMTS, GPRS, EDGE)
release – the “release” field may contain up to three letter:
1 – Type of platform, such as F
2 - Type of mobile modem used, such as A
3 – Standard or special requirements
package - P - plastic, M - metal
Examples:
topex-0.5.9-cdma-nad-p.trx
orange-3.0.1-FA-O.trx
topex-3.0.6-FA-S