72
Commands
LTB
Trigger band for RTA mode (corresponds to Measurement Trig-
ger mode Trigger band setting)
Only valid if the unit is currently in
L
p
mode (except pause). In other
cases, error 0003 is returned.
Setting command
LTB p1 p2
Parameter Content
p1 = 0
SUB AP
p1 = 1
MAIN AP
p1 = 2
16 Hz
p1 = 3
31.5 Hz
p1 = 4
63 Hz
p1 = 5
125 Hz
p1 = 6
250 Hz
p1 = 7
500 Hz
p1 = 8
1 kHz
p1 = 9
2 kHz
p1 = 10
4 kHz
p1 = 11
8 kHz
p1 = 12
16 kHz
p2 = 0
Bottom band
p2 = 1
Center band
p2 = 2
Top band
* To specify a 1/3 octave band, use p1 to specify the octave band,
and p2 to specify the bottom/center/top band for the trigger.
Request command
LTB ?
Response data
d1,d2
Return value
Content
* Same as for setting command
* d1 indicates octave band, and d2 indicates bottom/center/top
band.