![Renkforce RF2000 v2 BSS Operating Instructions Manual Download Page 85](http://html1.mh-extra.com/html/renkforce/rf2000-v2-bss/rf2000-v2-bss_operating-instructions-manual_1441509085.webp)
85
Setting the determined values
To set the value, first open the item "
Configuration
" in the menu and then the item "
General
".
Navigate to "
Extruder Offset X
" and press
OK
(2).
Set the determined value for the offset X with the two buttons "
up
" and "
down
" (1).
Confirm with
OK
button (2).
Navigate to the item "
Extruder Offset Y
" and press
OK
(2) again.
Set the determined value for the offset Y with the two buttons "
up
" and "
down
" (1).
Confirm the selection again with the
OK
button (2).
When you have set the values, print the cube again and check the offset. If the layers of the 2 extruders are not precisely on top of
each other yet, correct the values and print out the cube again. Repeat this until the layers are precisely on top of each other.
If the layers of extruder 1 protrude on both sides, the extruders may not have the same height. In this case, perform a heat bed scan
and particularly observe when lowering the 2nd extruder that it is supported as well on the heat bed as the 1st extruder.