Error:
Park Heat Bed
Operation denied
Is displayed when someone tries to start park head bed while printing/milling is active.
Can be caused by:
- M3080
- the menu item "Park Heat Bed"
This function is currently switched off by default.
Error:
Pause
Home unknown
Is displayed when printing/milling cannot be paused because the home position is not known.
Can be caused by:
- M25
- Emergency Pause
- the menu item "Pause Print"
- the menu item "Pause Mill"
- the hardware button "Pause"
This error theoretically should never happen.
Error:
Pause
Operation denied
Is displayed when printing/milling cannot be paused because printing/milling is not currently active.
Can be caused by:
- M25
- the hardware button "Pause"
Error:
Z Compensation
Invalid Matrix
Is displayed when the Z-compensation cannot be activated (or the Z-compensation matrix cannot be displayed)
because the Z-compensation matrix is not present or invalid.
Can be caused by:
- M3001
- M3013
- M3141
- M3153
Error:
Z Compensation
Home unknown
Is displayed when Z-compensation cannot be activated because the home position is not known.
Can be caused by:
- M3001
- M3141
Error:
Z Compensation
Operation denied
Is displayed when the Z-compensation matrix cannot be changed or deleted because:
- the Z-compensation is currently active
Error:
Find Z Origin
Operation denied
Is displayed when the RF is in "Printer" mode.
Error:
Home
Operation denied
Is displayed when the "Home" position cannot be targeted because:
- printing/milling is underway
- a heat bed scan is underway
- a work piece scan is underway
- search for the Z-origin is underway
- the DMS-test is underway
Error:
Change Mode
Operation denied
Is displayed when the operating mode cannot be changed because:
- printing/milling is underway
- a heat bed scan is underway
- a work piece scan is underway
- search for the Z-origin is underway
- the DMS-test is underway
Can be caused by:
- the menu item "Mode"
Error:
Change Z Type
Operation denied
Is displayed when the Z-type cannot be changed because printing/milling is currently underway.
Can be caused by:
- the menu item "Z Type"
Error:
Change Hotend
Operation denied
Is displayed when the hotend type cannot be changed because printing is currently underway.
Can be caused by:
- the menu item "Hotend"
Error:
Change Miller
Operation denied
Is displayed when the mill type cannot be changed because milling is currently underway.
Can be caused by:
- the menu item "Miller"