This cube is also very suitable for setting the extruder offset for X and Y. You can find the functions "
Extruder Offset X
" and "
Ex-
truder Offset Y
" in the menu, under "
Configuration
" - "
General
".
This setting corrects the distances of the two extruders. X corrects the distance between the two extruders, i.e. when the printed
object is offset to one side. Y corrects the distance when the extruders are offset backwards or forwards, because one part of the
cube is too far at the front and the other too far at the back.
Important! The reference extruder is always the left one (extruder 0). See chapter "19. c) Fine adjustment of the two extruders" in