Error:
Delete File
Operation denied
Is displayed when a file cannot be deleted from the SD card because printing/milling is currently underway.
Can be caused by:
- M30
- the menu item "Delete File"
Error:
X-Axis
Home unknown
Is displayed when the X-axis cannot be moved because the home position is not known.
Can be caused by:
- the menu item "Position X"
Error:
X-Axis
Operation denied
Is displayed when the X-axis cannot be moved because printing/milling is currently underway.
Can be caused by:
- the menu item "Position X"
Error:
Y-Axis
Home unknown
Is displayed when the Y-axis cannot be moved because the home position is not known.
Can be caused by:
- the menu item "Position Y"
Error:
Y-Axis
Operation denied
Is displayed when the Y-axis cannot be moved because printing/milling is currently underway.
Can be caused by:
- the menu item "Position Y"
Error:
Z-Axis
Home unknown
Is displayed when the Z-axis cannot be moved because the home position is not known.
Can be caused by:
- the menu item "Position Z"
- the hardware button "up"
- the hardware button "down"
Error:
Extruder
Operation denied
Is displayed when the extruder cannot be moved because it is too cold.
Can be caused by:
- the hardware button "Extract"
- the hardware button "Retract"
- the menu item "Load Filament"
- the menu item "Unload Filament"
- the menu item "Position Extruder"
Error:
Align Extruders
Operation denied
Is displayed when the alignment of the two extruders cannot be started because:
- Printing is currently being performed
- Only one extruder is installed
Error:
Align Extruders
Temperature wrong
Is displayed when the alignment of the two extruders cannot be started because:
- The temperature difference between extruder 1 and 2 is too high
Error:
Determine PID
Temperature wrong
Is displayed when it is found during automatic determination of the PID values that the actual temperature is
getting too high.
Can be caused by:
- M303
Error:
Determine PID
Timeout
Is displayed when automatic determination of the PID values cannot be completed within 20 minutes.
Can be caused by:
- M303
Error:
Temperature Manager
Sensor Error
Is displayed when a temperature sensor error is found (= the sensor returns a temperature < -10 or > +300 °C).
The firmware must be restarted before the temperature sensors will be evaluated again.
Error:
Emergency Z Block
Is displayed when all other movements in Z-direction are blocked due to too-high DMS values.
The firmware must be restarted before movement in the Z-direction is possible again.
Warning:
Emergency Pause
Is displayed when the current print/milling process has been paused due to too-high DMS values.
To continue printing/milling, push the "Continue" button.