LubriMist
®
Model IVT
Oil Mist Generating System
Installation and Operating Manual
Page 92
of 256
PROGRAM IN
NORMAL RUN
MODE
SET
<VARIABLE>
HIGH XXX
SET POINT
CORRECT?
PRESS
[SET]
KEY
PRESS [INC] &
[DEC] KEY TO
ACHIEVE SET
POINT
PRESS
[CLEAR]
PRESS
[FUNCTION]
KEY
PRESS
[ENTER]
KEY
SET
<VARIABLE>
LOW XXX
SET POINT
CORRECT?
PRESS [INC] &
[DEC] KEY TO
ACHIEVE SET
POINT
PRESS
[ENTER]
KEY
YES
YES
NO
NO
YES
START
PROGRAM IN
NORMAL RUN
MODE
END
NOTE; Set Point change are not saved if the [CLEAR] key is pressed during the key sequence.
The key sequence must be completed in order and in its entirety for changes in set points to be
established.
For setting alarm set points for the following operating
<FUNCTIONS>
:
1. Oil Temp = Bulk Reservoir Oil Temperature
2. Oil Level = Bulk Reservoir Oil Level
3. Sup Air Press = Supply Air Pressure
4. Reg Air Press = Regulated Air Pressure
5. Sup Oil Press = Supply Oil Pressure
6. Mist Press = Mist Pressure
7. Mist Dens = Mist Density
Key Sequence diagram For Setting High And Low
Set-points Of Variables Without Control Set-points