Auto Bulk Oil Fill
The IVT Oil Mist Generator Auto Bulk Oil Fill system uses supply oil from a centralized bulk oil
supply system connected to the IVT Oil Mist Generator to operate. To commission the Auto Bulk
Oil Fill system:
A.
Connect the Bulk Oil Supply at the block valve located at the rear of the IVT cabinet.
B.
Insure that the centralized bulk oil supply system has been commissioned and operating.
C.
Open the oil supply block valve to the IVT Oil Mist Generator auto bulk oil fill system.
D.
Open left cabinet door to the IVT. Locate the oil supply pressure gauge located next to
the solenoid operated oil valve. Adjust supply oil pressure to manufactures suggested
pressure range insuring not to exceed 300 PSI (21 Bar).
E.
Ensure that the IVT Oil Mist Generator cabinet doors are closed and that the door latch is
secured in the closed position.
F.
Oil filter element (P/N 77-500-487) should be changed on a semi-annually basis.
NOTICE:
The lubricants dispensed by this equipment are to have
flash points greater than 200
°
F (93
°
C).
Open Block Valve
Check Supply Oil
Pressure
Change Oil Filter
Element Semi-