2) When the auxiliary oil mist generator is put on line, the supply air pressure opens the outlet to
the auxiliary oil mist generator discharge and the regulated air pressure closes the discharge
to the main unit.
TO AUXILIARY UNIT
AIR SUPPLY
AUXILIARY OIL MIST GENERATOR
AIR SUPPLY BLOCK VALVE
AUXILIARY OIL MIST GENERATOR
AIR PRESSURE REGULATOR
MIST OUTLET
FROM AUXILIARY
UNIT
MIST OUTLET
INLET AIR
3) If the block valves to both oil mist generators are inadvertently placed in the open position at
the same time, because the supply air pressures are higher than the regulated air pressures,
both valve poppets move up to the open position.
MAIN OIL MIST GENERATOR
AIR SUPPLY BLOCK VALVE
AUXILIARY OIL MIST GENERATOR
AIR PRESSURE REGULATOR
AUXILIARY OIL MIST GENERATOR
MIST OUTLET
INLET AIR
AIR SUPPLY BLOCK VALVE
MAIN OIL MIST GENERATOR
AIR PRESSURE REGULATOR
FROM AUXILIARY
UNIT
MIST OUTLET
FROM MAIN UNIT
MIST OUTLET
TO AUXILIARY UNIT
AIR SUPPLY
AIR SUPPLY
TO MAIN UNIT