![RelaDyne LubriMist IVT Installation And Operating Manual Download Page 31](http://html1.mh-extra.com/html/reladyne/lubrimist-ivt/lubrimist-ivt_installation-and-operating-manual_1435628031.webp)
LubriMist
®
Model IVT
Oil Mist Generating System
Installation and Operating Manual
Page 31
of 256
Regulated Air Pressure Transducer
The incoming air supply to the mist generator is controlled using a manually operated air pressure
regulator. The air pressure regulator adjusts and controls the airflow through the mist head by
controlling the inlet air pressure. Once the oil mist system has been commissioned, only minor
adjustments to the regulated air pressure is needed to maintain proper system operation. The
regulated air pressure transducer is located on the main oil mist-generating head. It is a two-wire
4-20 mA output pressure transducer. It is connected to the IVT controller with an integral flexible
cord. The transducer provides the signal for high regulated air pressure alarm and low regulated
air pressure alarm. During operation the signal is used to provide an operating regulated air
pressure value.
Regulated Air Pressure
Transducer
View A-A