LubriMist
®
Model IVT
Oil Mist Generating System
Installation and Operating Manual
Page 121
of 256
Modscan Configuration
Start Modscan program in the host computer.
See Figure 1
Modscan screen
figure 1
1. The device ID in the Modscan screen has to be the same as the slave address in the IVT.
(a) The device ID’s parameters are (1 to 247).
(b) The IVT’s parameters are (001 to 247),
Note 001 is the same as 1.
2. To set the rest of the parameters in the Modscan screen, click the connection button in the
menu bar and then click Connect.
(Connection Detail screen) will appear, fill in all that apply.
See Figure 2
Connect Using
----- Select port to be used.
Configuration
Baud Rate: 9600 --- set the same as IVT
Word length: 8 --- IVT’s default is 8
Parity: Even --- set the same as IVT
Stop Bits: 1 -- IVT’s default is 1